background image

2

• Low concentrations of OVG
• 

Low concentrations of 

Volatile

  Organic Compounds (VOC)
• Unpleasant nuisance odors

• Lung-damaging particles
• Metal fumes
• Smoke
• Mold and fungal spores

PREDATOR Portable Air  Scrubber

Model: PRED1200

Instruction Manual

©

 Abatement Technologies 2006 All Right s Reserved.  No reproduction of any portion of this work is permitted without the

express written permission of Abatement Technologies,  Inc.

READ AND SAVE THESE INSTRUCTIONS!

Note:   1. Read and understand all operating instructions before using the PRED1200 Portable Air

Scrubber.

 2. Save this manual for future reference.

This instruction manual provides important information on the use of the Predator Portable Air Scrubber (PAS) -
model PRED1200.  These instructions must be carefully followed in order to operate the unit safely and correctly.
If there are any questions regarding the use of the unit, please contact Abatement Technologies immediately at
800-634-9091 U.S. or 905-871-4720 Canada.

Abatement Technologies strongly urges users of air filtration units and related accessories to follow the most
recent guidelines and/or standards published by the Occupational Safety and Health Administration, Environmental
Protection Agency, and all other federal, state, provincial and local regulations.

GENERAL  INFORMATION

The PRED1200 is a multi-use air filtration device, equipped with pre-filters and a HEPA filter that are capable of
filtering many airborne contaminants. An optional carbon pre-filter for capturing low concentrations of odors,
vapors, gases, and volatile organic compounds, collectively known as OVG, is also available.

Types of contaminants captured by particulate pre-filters, HEPA filter, or carbon filters:

• Dirt
• Dust
• Drywall dust
• Saw dust

Note: To capture low concentrations of OVG, a Vapor-Lock

®

 carbon filter must be used.

The PRED1200 is capable of providing particulate and odor, vapor, gas filtration with final stage filtration through
a High Efficiency Particulate Air (HEPA) filter. The  PRED1200 incorporates a series of particulate filters which
successively remove larger size to smaller size particles from the air. In addition to providing HEPA filtration, the
PRED1200 is primarily used in a negative pressure or recirculation mode.  A negative pressure condition is
created in order to confine contaminated airborne particles. This condition exists when the static pressure inside
the room containing the unit is lower relative to the pressure of the environment outside the room. The static
pressure differential is created and maintained by continuously exhausting air out of a given room at a faster rate
than air enters the room from all other sources. In the recirculation mode, all of the filtered air is exhausted back
into the room containing the unit.

Standard Air Cleaning Stages (filters supplied with the unit)

The PRED1200 comes equipped with two progressively efficient particulate pre-filters mounted in the pre-filter
compartment, and a final stage HEPA filter, located in the lower section of the cabinet:

The first-stage 1"-deep, coarse particulate pre-filter (F621) is designed to capture particles 100 microns
or larger.

The second-stage 2"-deep, pleated pre-filter (H502) is designed to capture particles 10 microns or
larger.

Each HEPA filter (H610C-99) is tested & certified to capture at least 99.97% (9,997 out of 10,000) 0.3-
micron particles.

Summary of Contents for PRED1200

Page 1: ...1200 ModelPRED1200 ModelPRED1200 ModelPRED1200 ModelPRED1200 INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL INSTRUCTION MANUAL Abatement Technologies Ltd Ontario Canada 905 871 4720 Abatement Technologies Inc Georgia USA 800 634 9091 PRED1200MNL rev 6 30 2009 Abatement Technologies Inc Remediation Products Division www abatement com Patented U S Design Patent No D572 3...

Page 2: ...Pre filter P N H502 3 OptionalThird Stage 2 High Capacity Vapor Lock Carbon Filter P N VL1002 4 Final Stage 99 97 HEPA Filter P N H610C 99 5 Motorized Impeller 6 8 Rear Wheels 7 360 Swivel Casters 8 Pre filter Access Door 9 HEPA Filter Access Panel 10 Control Panel 11 Exhaust Outlet ...

Page 3: ...y known as OVG is also available Types of contaminants captured by particulate pre filters HEPA filter or carbon filters Dirt Dust Drywall dust Saw dust Note To capture low concentrations of OVG a Vapor Lock carbon filter must be used The PRED1200 is capable of providing particulate and odor vapor gas filtration with final stage filtration through a High Efficiency Particulate Air HEPA filter The ...

Page 4: ...re accurate rule of thumb than one s sense of smell Since off gassing of adsorbed OVG can occur when the adsorption capacity of the filter is reached replace the carbon filter as soon as odor breakthrough is sensed More detailed information on carbon adsorption can be found in an article titled Activated Carbon How Is It Used How Does It Work which can be found on the Links and Articles page of th...

Page 5: ...ary start up current surge the unit requires a 15 amp circuit that is free of other loads 3 Extension cords used for the PRED1200 must be UL listed heavy duty No 14 3 AWG industrial grade 3 wire type Use of larger numerical gauge lower capacity wire power cord s may result in electrical shock fire hazards and or damage to unit The cord s must be in good condition and in continuous lengths no splic...

Page 6: ...of electrical shock Can cause injury or death Turn unit OFF and disconnect power cord from supply receptacle before replacing the HEPA filter and before cleaning or servicing the unit Warning The PRED1200 is equipped with an automatic restart motorized impeller that will restart without warning after a temporary power interruption or recovery from a thermal overload over heating condition Keep cle...

Page 7: ...ing the total amperage draw BEFORE OPERATING THE UNIT NOTE THE FOLLOWING Inspect and tighten any HEPA filter retaining nuts that may have loosened during transportation Inspect the filters for any material or structural damage prior to use and replace any damaged filters before operating the unit When removing any filters prior to operation always put them back in place with airflow indicator on f...

Page 8: ...nel are in place and closed DAISY CHAINING Daisy Chaining refers to the operation of multiple units on one circuit with only one of the units plugged into a 120V 15A electrical power supply receptacle Each subsequent unit is plugged into one of the GFCI receptacles on the prior unit up to the maximum number allowed based on the amperage draw per unit The National Electrical Code limits the total a...

Page 9: ...usable therefore do not attempt to clean and reuse them Caution Abatement Technologies PRED1200 Portable Air Scrubber units are designed to meet or exceed standards for high efficiency air filtration equipment Use only Abatement Technologies parts including replacement filters Use of non Abatement Technologies parts and filters voids the product warranty and all performance claims Warning To reduc...

Page 10: ...e HEPA filter retaining bracket in place slide the bracket off the long filter retaining bolts and remove the HEPA filter 4 Carefully place a new HEPA filter part H610C 99 into the cabinet making sure that it rests on the curved section of the cabinet base which is just behind the long lower filter retaining bolt The foam seal of the filter should be aligned with the exhaust outlet 5 Place the HEP...

Page 11: ...r o o d d e g n i h g n i t a r e p o y s a E s s a p y b r e t l i f t s n i a g a t c e t o r p o t r e t l i f e r p e g a t s t s r i F 1 2 6 F r e t l i f e r p e t a l u c i t r a p e s r a o c 1 r e t l i f e r p e g a t s d n o c e S 2 0 5 H r e t l i f e r p e t a l u c i t r a p d e t a e l p 2 e r p e g a t s d r i h t l a n o i t p O r e t l i f 2 0 0 1 L V r e t l i f n o b r a c y t ...

Page 12: ...E V O M E R H T I W E C N A D R O C C A N I E G N A H C S N O I T C U R T S N I G N I T A R E P O T C U D X E L F F O H T G N E L S D N E B E C U D E R S N O I T C I R T S E R E T A N I M I L E R O M O R F R E T L I F N O B R A C E V O M E R G A B Y L O P Note If the unit does not start or malfunctions after carefully following the Troubleshooting Guide callAbatement Technologies service departmen...

Page 13: ...om defect and to conform to specifications shall be held for Purchaser s shipping instructions which instructions Purchaser shall furnish promptly upon request ATI s liability shall in no event extend beyond replacement repair or refund of the purchase price and ATI shall not be liable under any circumstances for special contingent or consequential damages nor for loss damages or expenses directly...

Page 14: ...13 ...

Page 15: ...14 ...

Page 16: ...15 ...

Reviews: