P. 74 - Chap. 10 Maintenance
G
B
Changing the oil
Change the oil at the frequency indicated in the scheduled maintenance table of paragraph 10.2 or when you
plan to use a different oil from that in the machine.
Carry out this operation when the oil is still warm so that its viscosity is low and fluidity high.
Caution: lubricant temperature must not be sufficient to cause burns.
Proceed as follows:
Remove the front panel
PF
using the
key provided
Loosen oil filler plug
TO
. Be careful not
to lose the seal (
Fig. 43
)
Connect fitting
R
provided, which must
communicate with a suitable collection
recipient, to fitting
DO
after unscrewing
the safety plug (
Fig. 44
)
Open drain valve
RSO
and drain the
lubricant (
Fig. 44
)
After draining, close oil drain valve
RSO
Refill with oil as described in the “
Check-
ing oil level/topping up” paragraph
(
Fig. 43
)
Check that the seal of plug
TO
is cor-
rectly positioned and fasten the plug (not
too tightly)
Replace the front panel
PF
using the key
provided
Open the shut-off valve between the
compressor and the distribution line.
Switch the circuit breaker on and carry
out a test start-up.
Let the compressor run for a few minutes
and then make a visual inspection for
any oil leaks
Check the oil level again as indicated
in the “
Checking oil level/topping up
”
and if necessary top up
Fig. 43
Fig. 44
TO
R
DO
RSO
Summary of Contents for GENESIS Series
Page 1: ...GENESIS FORMULA MODULO 5 5 15 kW USE AND MAINTENANCE HANDBOOK GB...
Page 2: ......
Page 82: ...P 80 Chap 12 Diagrams G B 12 Diagrams Hydraulic pneumatic plant diagram 12 1...
Page 85: ...P 83 Chap 12 Diagrams G B Power circuit wiring diagram 5 5 15 kW Machines with air dryer 12 3...
Page 86: ...P 84 Chap 12 Diagrams G B Power circuit wiring diagram 11 kW Machines with inverter 12 4...
Page 89: ...P 87 Chap 12 Diagrams G B Auxiliary circuit wiring diagram 11 kW Machines with inverter 12 7...