P. 73 - Chap. 10 Maintenance
G
B
Checking oil level, topping up and changing the oil
10.5
Before performing any maintenance operations read the operator safety precautions in
chapter 5 carefully. These precautions must be followed scrupulously for all maintenance
operations
Checking oil level and topping up
Check the level of the oil in the machine circuit frequently when the machine has been stopped for at least
thirty minutes.
This operation is very simple: inspect the oil level on the level reference tube
TRL
(
Fig.41
) after disassembling
the front panel
PF
The oil level must be visible but must not exceed the
RLMAX
maximum level reference.
When the level of the lubricant is close to the minimum limit of the level reference tube
TRL
, top up the oil.
Never let the oil drop to a level which is no longer visible through the reference level tube
TRL!
Maximum level is reached when the oil laps the edge of the maximum level reference
RLMAX
during top-up
.
Top up when required, as follows:
Remove the front panel
PF
using the
key provided
Loosen oil filler plug
TO
. Be careful not
to lose the seal (
Fig. 42
)
Use a funnel to pour oil into the filler
sleeve (
Fig. 42
)
Top up the oil level using only the
amount indicated in paragraph 4.7
Avoid too much oil!!! Ensure the
level of the oil does not exceed the
maximum reference level RLM (Fig.
41)
Check that the seal of the plug is cor-
rectly positioned and fasten the plug (not
too tightly)
Replace the front panel
PF
using the
key provided
Fig. 41
Fig. 42
TRL
RLMAX
RLMIN
TO
Summary of Contents for GENESIS Series
Page 1: ...GENESIS FORMULA MODULO 5 5 15 kW USE AND MAINTENANCE HANDBOOK GB...
Page 2: ......
Page 82: ...P 80 Chap 12 Diagrams G B 12 Diagrams Hydraulic pneumatic plant diagram 12 1...
Page 85: ...P 83 Chap 12 Diagrams G B Power circuit wiring diagram 5 5 15 kW Machines with air dryer 12 3...
Page 86: ...P 84 Chap 12 Diagrams G B Power circuit wiring diagram 11 kW Machines with inverter 12 4...
Page 89: ...P 87 Chap 12 Diagrams G B Auxiliary circuit wiring diagram 11 kW Machines with inverter 12 7...