User’s Manual Version 1.3
Airolinx Wireless Serial-Ethernet Server
STW-601C
- 16 -
Configuring DNS
[Main]
Æ
[2 Networking]
Æ
[2 DNS Settings]
Fill in DNS information on the LAN Settings field. Alternatively, click on DHCP to obtain auto IP address,
gateway, subnet mask and DNS server.
Fig. 18. DNS Settings by Telnet
Configuring SNMP
Operation: [Main]
Æ
[2 Networking]
Æ
[3 SNMP Settings]
Enable SNMP by checking “Enable”; fill in network identification information on SNMP and click on the
“Save Configuration” button to save the changes. The changes will not become effective until STW is
restarted.
Serial Server supports basic SNMP function about system MIB (Management Information Base). For
example, these are SysName (System Name), SysLocation (System Location) and SysContact (System
Contact) in SNMP settings. These ones will response and supply basic system information from standard
SNMP query.