7
Trouble shooting - indication of malfunction
7.1
Trouble shooti
ng
If you have problems operating your max-e, see whether you can remove
them with the help of the following instructions
.
7.2
Indication of malfunction
The display indicates malfunction as follows
.
7.2.1
Possible indication of malfunction
F
All indicated malfunctions can be confirmed by the + key
.
27
max
-
e
Problem
Check and potential problem solving
max-e cannot be turned on
Is the charger connected to the max-e?
If so, disconnect the charging cable and plug in the power cable
Is the battery pack or the control unit empty?
If so, charge the batteries and the control unit.
Are the fuses damaged?
If so, exchange the fuses.
Ist das Problem immer noch vorhanden?
Wenn ja: Fachhändler verständigen.
Batteries don't charge
Please contact your dealer
Power shafts do not emerge on one or
both sides
Loosen set screw of the horizontal adjustment (located directly on the
housing) and screw it tight again (check the mounting width).
Pressure is not reached
Loosen set screw of the horizontal adjustment (located directly on the
housing) and screw it tight again (check the mounting width).
If there is still a problem, please contact you dealer.
Malfunction of the control unit
Explanation
Low voltage
Batteries of the control unit are under voltage
Parameter
Parameter in EEPROM false
Software
Error when running the control unit's software
Unidentified
Invalid error code (error of software)
Error!
Drive
Pressure not reached
Acknowledge with +