AAS 16-X1 ASCENT X1 Installation And Operating Manual Download Page 7

Page 7 American Access Systems / Security Brands, Inc.

THE IDLE MODE

When the desired connections are complete and power is supplied to the unit, the unit will be in the IDLE MODE. The 

IDLE MODE is the normal mode of operation, meaning the unit is ready to accept input from the keypad.  When in 

the IDLE MODE, you have approximately 4 seconds between key presses.  If this time is exceeded, you will receive an 

ERROR TONE.  Any time you hear an ERROR TONE, simply begin whatever operation you were attempting over again.

ACCESS CODES AND FUNCTION CODES

There are two types of codes you need to keep in mind when using the Ascent X unit.

• Access Codes, quite simply, are the numbers that are programmed into the unit and assigned to the users who 

need to access the gate or door.  The Access Codes are the “everyday” use codes.  Up to 1000 Access Codes can 

be programmed into the unit.  

• Function Codes, on the other hand, are special modes that only the Master User or Administrator can enter to 

control how the Asecnt X unit is programmed and operates.  There are 3 specialized Function Codes which are shown 
on the following Chart. 

MASTER CODE

The Master Code is a four-digit Function Code used 

to program Access Codes into the Asecnt X unit. The 

factory default master code is 1 2 5 1.The Owner/

Administrator enters the Master Code to program the 

Access Codes others will use to gain entry to the area 

controlled by the unit.   It is recommended that the 

Master Code be re-programmed to a four-digit code 

of your choice.   Remember to make a note of the new 

Master Code.

LATCH CODE

The Latch Code is a programmable four digit Function 

Code used to toggle relay A.  The Latch Code is used 

to hold a gate or door open.  For example, the home 

owner or business administrator wants leave the gate 

open for a period of time; say for a few hours during 

a party or special function.  While the Latch Code is 

entered, the gate or door is open.  Re-enter the Latch 

Code to return the unit to normal operation (to close 

and lock the gate or doorway.)  

SLEEP CODE

The Sleep Code is a programmable four digit Function 

Code which, when entered, disables all codes. No one 

can use any of the Access Codes while the unit is in the 

SLEEP mode.  An example is if the user wants to deny all 

access to a gated area for a period of time, he or she 

enters the SLEEP CODE which essentially locks the unit.  

Re-enter the Sleep Code to return the unit to normal 

operation.   An override code is provided.

Summary of Contents for 16-X1 ASCENT X1

Page 1: ...16 X1 Cellular Telephone Entry System Installation and Operating Manual www americanaccess com Your Partner in Access Control...

Page 2: ...Codes Sub Mode 1 10 Delete Individual Access Codes Sub Mode 2 11 Change the Master Code Sub Mode 3 11 Set Sleep Code Sub Mode 4 12 Set Latch Code Sub Mode 5 13 Set Relay Output Times Sub Mode 6 13 Pro...

Page 3: ...purchase Contact the original dealer or installer of the product and return your AAS product along with the receipt to them If you have problems locating the dealer or installer contact American Acce...

Page 4: ...Transformer 4 20 X carriage bolts 4 20 hex nuts Tools Needed For Basic Installation Wire nuts or appropriate terminals connectors Wire strippers Wire cutters 3 8 drive ratchet 6 extension 7 16 socket...

Page 5: ...rating both normally open N O and normally closed N C contacts An external event trigger programmable as a Remote Inactive Arming or Remote Open input INSTALLATION MOUNTING THE UNIT The tools and inst...

Page 6: ...you are connecting to a gate operator Overhead door or electric door strike use the COM and N O terminals for normally open contact b If you are connecting to a mag lock or any device that requires po...

Page 7: ...CODE The Master Code is a four digit Function Code used to program Access Codes into the Asecnt X unit The factory default master code is 1 2 5 1 The Owner Administrator enters the Master Code to prog...

Page 8: ...y entering the Master Code using the keypad If the correct Master Code is entered the unit will reply with a GOOD TONE and the Yellow LED will illuminate In the Program Mode you have approximately 30...

Page 9: ...ght and a GOOD TONE will sound You can now enter any of ten programming SUB MODES described below SUB MODE NUMBER CODE DESCRIPTION 1 Program an Access Code s Relay A 2 Delete an Access Code 3 Change M...

Page 10: ...ssigned and you must select another code If you make a mistake during entry press the star key then re enter the code When a new code is accepted the unit will sound a GOOD TONE Continue to enter code...

Page 11: ...n memory the unit will respond with an ERROR TONE and wait for another code to be entered A GOOD TONE will sound once the code has been found and deleted You may continue deleting codes until you are...

Page 12: ...flash every 3 seconds To initialize the system back tonormal simply re enter the Sleep Code Should you lose or forget the Sleep Code and the unit is in the sleep mode you must complete a Master Reset...

Page 13: ...Code is accepted you will hear a GOOD TONE Press the pound key to exit the programming mode Now when the new Latch Code is entered the RED LED will light and the gate will hold open When the new Latch...

Page 14: ...unit will revert to the IDLE MODE and will operate normally To toggle the Three Strikes You re Out feature on or off Enter the current Master Code Unit will sound a GOOD TONE Press the numeral 8 and...

Page 15: ...an Arming Circuit Enter the MASTER CODE Unit will sound a GOOD TONE Enter the numeral 9 Unit will sound the Current Mode followed by a GOOD TONE Enter the numeral 2 Unit will sound a GOOD TONE 3 To p...

Page 16: ...ase all Access Codes entered This action will not change the Master Code To erase all Access Codes and Function Codes Enter the Master Code The 1 2 5 1 cannot be deleted Enter the numeral 0 Both the R...

Page 17: ...aster Code to the 1 2 5 1 Should be used if the unit is in the Latch or Sleep Mode and the Latch or Sleep code is lost or forgotten When a Master Reset is performed Access Codes and Functions Codes ar...

Page 18: ...ALL ACCESS CODES and FUNCTION CODES are lost when performing a Unit Reset Follow these steps exactly If you make an error an ERROR will occur a low pitch ERROR tone will sound and you will need to sta...

Page 19: ...timer circuit from overriding the keypad when it is in a latch mode Contact Gate Operator manufacturer When I enter a valid Access Code the gate does not open Locate the two wires attached to the Brow...

Page 20: ...our Technicians assist you E Mail customerservice securitybrandsinc com Technical Support 303 799 9757 Technical support is available free of charge Hours are 8 00 a m to 4 30 p m MST If you call plea...

Page 21: ...Page 21 American Access Systems Security Brands Inc Notes Use this space to keep a record of Access Codes and the MASTER Code...

Page 22: ...Page 22 American Access Systems Security Brands Inc Notes Use this space to keep a record of Access Codes and the MASTER Code...

Page 23: ...Page 23 American Access Systems Security Brands Inc Notes Use this space to keep a record of Access Codes and the MASTER Code...

Page 24: ...Your Partner in Access Control www securitybrandsinc com SECURITY BRANDS INC...

Reviews: