![AAS 16-X1 ASCENT X1 Installation And Operating Manual Download Page 13](http://html1.mh-extra.com/html/aas/16-x1-ascent-x1/16-x1-ascent-x1_installation-and-operating-manual_449552013.webp)
Page 13 American Access Systems / Security Brands, Inc.
Set Latch Code -- Sub-Mode 5
DETAILS: The Latch Code toggles the state of the main relay (A) of the circuit board. The red LED will remain lit while
the relay is in the latched position. The latch code is useful in applications where the gate is desired to hold open. If
the operator’s close circuit is controlled by loops, timers, etc., they will be overridden by the latched state of the relay
and the gate will hold open. An “OPEN-OVERRIDE” circuit must exist in the operator in order to utilize this function. If
your gate cycles when this code is entered, your operator is not set up to utilize this function. Your local dealer or
distributor should be able to assist you if you have any specific questions.
To program or change the Latch Code:
• Enter the current Master Code
• Press the numeral 5
• Enter a new Latch Code (If you hear an ERROR TONE, select another code that is not already in use
• If you make an entry error, simply press the star (*) key and enter the number you wish
• When a new Latch Code is accepted you will hear a GOOD TONE
• Press the pound (#) key to exit the programming mode
• Now, when the new Latch Code is entered, the RED LED will light and the gate will hold open
• When the new Latch Code is entered a second time the RED LED will go off and the gate will close
NOTE: On gates with a closing timer, the “TIMED DURATION” begins when the Latch Code is released.
Set Relay Output Times -- Sub-Mode 6
To set or change a Relay Output Time:
• Enter the current Master Code • Press the numeral 6
• Enter the Relay numeral (1 = Relay A; 2 = Relay B)
• Enter the desired Relay Output Time in seconds (i.e., enter 060 for 60 seconds)
• Press the pound (#) key to exit the programming mode
Program Relay “B” Access Codes -- Sub-Mode 7
To program Relay “B” Access Codes:
• Enter the current Master Code
• Press the numeral 7
• Enter a new Relay B Access Code (If you hear an ERROR TONE, select another code that is not already in use)
• When a new Latch Code is accepted you will hear a GOOD TONE
• Continue to enter new Relay B Access Codes
• If the memory becomes full, you will not be able to add more Relay B Access Codes
• Press the pound (#) key to exit the programming mode
Note: If the memory is full, you will not be able to access Sub-Mode 7. You will hear an ERROR TONE
instead.