0x1F
SPANFREQ HF / HF-V4 / NF Modifies STOPFREQ as STA SPANFREQ.
0x10
PREAMPEN
HF-V4
Internal Pre-amplifier
0=OFF
1=ON
0x11 SWPDLYACC
HF-V4
Sweep delay for accuracy mode. 1 enables and 0
disables the delay.
0x12 SWPFRQPTS
HF-V4
Sweep frequency points request
0x13
REFOFFS
HF-V4
Manual calibration value in +- dB
0x20
USBMEAS
HF / HF-V4 / NF Measurement data to USB mode
0=OFF
1=ON
0x21 USBSWPRST HF / HF-V4 / NF Reset current sweep. If this variable is not
0, the current sweep is aborted and restarted
with current values of STARTFREQ and STOPFREQ.
0x22
USBSWPID HF / HF-V4 / NF USB sweep identification request
0x23 USBRUNPROG
HF-V4
Run SPECTRAN program
- FID_FACTSETUP 97 reset to factory
defaults
- FID_INICALREQ 98 (re)run initial
boot calibration
- FID_POWEROFF 99 switch unit off
additional P-Code programs can be run by their
file ID as well
0x30 LOGFILEID HF / HF-V4 / NF Log. file id. Write log file data to this file
(see Program 200).
0x31 LOGSAMPCNT HF / HF-V4 / NF Number of Samples to write to log file. After
each interval, this number is decremented and
then the program 200 is called.
0x32 LOGTIMEIVL HF / HF-V4 / NF If the sweep is finished before this interval
is reached, the log event isn’t generated.
0x41
SPECDISP HF / HF-V4 / NF Spectrum display mode
0=Limits Mode
1=Spectrum Mode
0x42
PEAKDISP HF / HF-V4 / NF Peak display mode. 0 shows the Frequency of
the markers in field 4-6 of the display and
the power in Fields 10-12, 1 is visa versa.
0x43 MARKMINPK HF / HF-V4 / NF Minimum Power to be treated as a marker.
0x44
RDOUTIDX HF / HF-V4 / NF The display shows a vertical line at this
pixel column and reports the value at this as
marker. The value -1 disables this feature.
0x45 MARKCOUNT HF / HF-V4 / NF Marker count
0x46 LEVELTONE
HF-V4
Peak level audio tone enable / disable
0x47
BACKBBEN
HF-V4
Background BB detector enable / disable
0x48
DISPDIS
HF-V4
Display update disable / enable
0x49 SPKVOLUME HF / HF-V4 / NF Internal Speaker volume. Floating point range
from 0.0 to 1.0
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
TestEquipmentDepot.com
Summary of Contents for Spectran V4
Page 26: ......
Page 34: ...System Overview This chapter describes all system overview pages...
Page 35: ...Spectran Server Overview Networkserver Settings Timestamp Device information...
Page 38: ...List of clients Shows a list of currently connected clients One row per client...
Page 40: ...Phone Add a contact phone number Contact Add a contact person...
Page 41: ...Server Logfile Shows information of the default logfile...
Page 46: ...System Configuration This chapter describes all system configuration pages...
Page 50: ...Main menu Main program menu...
Page 63: ...Save Information...
Page 66: ......
Page 67: ...Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...
Page 68: ......
Page 69: ...Save Information button...
Page 70: ...Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...
Page 75: ...Delete a selected profile from RSA This can t be undone...
Page 84: ...The file list shows all recorded files in the selected folder Folder list...
Page 105: ......