7
Table 1
Radio Perform. Parameter Values
Radio Perform.
Operating Characteristics
Best
Best range and responsiveness, shortest run-time
High
(Initial Value)
Very good range and responsiveness, better battery life than Best
Good
Good range and responsiveness, slightly longer battery life than
“High”
Save Power
Good range, reasonable responsiveness, more battery life than
“Good”
Long Run
Longest run-time, reasonable range and responsiveness
The actual-run time depends on temperature and whether the night-time display
illumination is used. In practical use, only small differences are noticeable between the
different settings above.
This parameter is local to the Handheld on which it is configured.
No access code is required to change this parameter.
6.2. Auto-Off
If no buttons are pressed on the Handheld, the Handheld will automatically turn
itself off after a prescribed period of time determined by this parameter:
Table 2
Auto-Off Parameter Values
Auto-Off
Time With no Buttons Pressed Before Automatic Power-off
Never
(Initial Value)
As long as the remaining battery charge allows for
5 min.
One-twelfth of an hour
10 min.
One-sixth of an hour
30 min.
Half an hour
This parameter is local to the Handheld on which it is configured.
No access code is required to change this parameter.
6.3. Reset all params to default?
This Config Mode screen will, if the YES (top rectangular) button is pressed twice
(the second time to confirm) cause all of the parameters to be changed to their initial
values. Then, the green button may be pressed to commit to the reset operation.
This function is protected and may be access only after entering the correct access
code (provided by Aarcomm Systems Inc. in a separate communication).