12
Cylinder explosion-proof valve (see the picture for structure )
Operating principle: The cylinder explosion-proof valve is placed at the oil inlet of the cylinder. It will be
prevent the dangerous of the platform dropping to fast when the oil pice suddenly broken.
Chapter 3 Installation
3.1 Installation conditions and environment
a. Altitude ≤1000m
b. Air humidity 30-90
%
c. Ambient temperature -5-40°C
d. Power
220V/380V, 50HZ/60HZ
e. The maximum vertical space for installation should be not less than 4m and the distance between
the lifts and obstacles such as wall should be not less than 2m.
3.2 Loading and unloading, transportation and storage
a. During loading and unloading, the acting force should not be directly exercised on the machine.
b. The transportation and storage temperature should be at -25-55
℃
. If it is higher then 70
℃
, the
transportation and storage should not be more than 24h.
3.3 Handling safety events and method
a. To handle the lift, please select proper lifting device according to machine weight to prevent from