Operators and Maintenance Manual
Display
EEM MOT 01 FE03.04
Page
9/16
Copyright:
Auto & Aero Technologies Sp. z o.o.
Mazowiecka 10/5, 20-723 Lublin, Poland
■
email: [email protected]
■
www.aatech.pl
Fig. 6. Display of the FE03.04 software version
On client’s request,
warning and alarm threshold values may be set for
some of the above parameters according to the specification provided by
the aircraft supplier. Default threshold values are listed in Table 2.
Tab. 2. Parameters displayed by EEM MOT 01 FE03.04 display
Lp.
Parameter
Symbol/
name
in display
Unit
Range of
bar graph
indicator
Warning/alarm thresholds
Warning
Alarm
1
Fuel level
FUEL
L
0
70 l
-------
--------
2
Oil pressure
OIL p
Bar
0
–
7,5 bar
from 1,0
to 2,5 bar
#
from 5,0
to 7,0 bar
under
1,0 bar
#
above
7 bar
2
Oil
temperature
OIL T
°C
0
–
140 °C
from 50
to 60°C
from 110
to 130°C
under
50°C
above
130°C
3
Voltage in
electric
power
instalation
V
0
20 V
from 11
to 12V
from 14
to 15V
under 11V
above 15V
4
Flight time
FT
H:min
-------
--------
5
Total engine
running time
HOBBS
H:min
-------
--------
6
Number of
recorded
threshold
crossings
E