background image

 

 

 

 

 

 

 

 

 

 

 

Version 1.0.2 

3

 

F

RONT 

P

ANEL

 

The ST-101 main display is shown in the following picture. 

 

The 

PWR/CLR

 on the lower left is used to Exit any screen or to turn the unit off. 

 

Keys 

F1

F2

, and 

F3

 are screen dependent. 

o

 

The 

F1 START

 key starts sending a signal at the currently set frequency. 

o

 

The 

AUTO-SET

 key initiates an automatic setup feature. The ST-101 will scan the pair and 

attempt to determine an optimum frequency and initial power 

LEVEL

 

The 

FREQ

 key allows for frequency selection. 

 

The 

LEVEL

 key is used to adjust the power output 

LEVEL

 when transmitting the signal.  

 

The 

CFG

 key allows the user to set the 

CONTRAST

BACKLITE

, and 

TONE

 mode options. 

 

The Charger jack (12V) is used to charge the internal battery. Only use the supplied charger to 
charge the ST-101 to avoid damage to the unit. 

 

The CHGR lights above the display has a red light when the charger is connected. A green light is on 
when the battery is charging. 

 

The pair cord plugs in on the right side of the case as indicated on the front panel. 

Summary of Contents for ST-101

Page 1: ...ST 101 Signal Transmitter Fault Location Transmitter User Manual Version 1 0 2...

Page 2: ...Allied Analogic Inc 132 Redtail Ct Weatherford TX 76088 817 599 0272 2017 AALogic Inc All rights reserved...

Page 3: ...te 4 5 2 2 Tone Configurations 4 6 Setup 4 6 1 Safety 4 6 2 Fault Pre Testing 4 6 3 Sectioning 5 6 4 Connections 5 6 5 Split Faults 5 7 Transmitting Signals 6 7 1 Frequency selection 6 7 2 AUTO SET 7...

Page 4: ......

Page 5: ...uses the signal to be radiated The highly sensitive receiver tuned to the same frequency as the transmitted signal allows the technician to locate the fault by observing the changes in the signal stre...

Page 6: ...imum frequency and initial power LEVEL The FREQ key allows for frequency selection The LEVEL key is used to adjust the power output LEVEL when transmitting the signal The CFG key allows the user to se...

Page 7: ...output The display is backlight and contrast adjustable by pressing the CFG key A battery charge indicator is in the top left corner Always check this before use If only one segment is shown charge t...

Page 8: ...ay not display the pulsed tone as well when locating a fault 6 SETUP The ST 101 is designed to simplify setup The directions provided with the receiver should be reviewed to ensure the best success in...

Page 9: ...ive fault as follows Fault Description Connections Short Tip connected to Ring Black to Tip and Red to Ring Ground Tip or Ring connected shield Black to sheath and Red to grounded wire Cross Tip or Ri...

Page 10: ...LECTION Pressing the FREQ key allows the user to select a specific frequency The ST 101 displays the recommended distance for each frequency The table below shows the recommendations and notes Section...

Page 11: ...frequency can be changed by pressing the FREQ key or the power level by pressing the LEVEL key as needed Always ensure the ST 101 and receiver are using the same frequency 7 Press F1 STOP to temporar...

Page 12: ...the transmitter operation when the clips have excessively high or low resistances connected to the pair clips 7 4 1 Low Current High Resistance or Open Low current occurs when the resistive fault is t...

Page 13: ...wing table to resolve the error Procedure Solution Check the Clips Ensure the clips and wire are not shorted Measure the fault with a test set The cable pair maybe shorted at the connection point Decr...

Page 14: ......

Page 15: ...e Charge 0 to 45c 32 to 113F Operate 20 to 60c 4 to 158F Storage 20 to 60c 4 to 158F Fault Limits Typical Resistive Fault Limits 1000 ohms Cable Diameter 1 2 3 Short 75K 50K 25K Ground 100K 75K 75K Cr...

Page 16: ......

Page 17: ...r s 4 Press F1 START 5 Set the receiver to the indicated frequency 6 Press F1 OK 7 Use the receiver to check for tone on the cable adjust receiver gain 8 Press LEVEL and adjust the power output level...

Reviews: