Version 1.0.2
13
9
ST-101
Q
UICK
R
EFERENCE
9.1
S
ETUP
1.
Charge all equipment
2.
Test to determine the type of resistive fault
3.
Estimate the distance to the fault
4.
Section and isolate the section
5.
Estimate the length of the section
6.
Apply a short at the far end if the fault is a split
7.
Use AUTO-SET or Manual mode to start transmitting the signal using the steps below.
9.2
AUTO-SET
1.
Turn on ST-101
2.
Press
F3
AUTO-SET
3.
Connect the clips to the pair(s)
4.
Press
F1
START
5.
Set the receiver to the indicated frequency
6.
Press
F1
OK
7.
Use the receiver to check for tone on the cable, adjust receiver gain
8.
Press
LEVEL
and adjust the power output level if needed
9.
Use the receiver instructions to locate the fault
9.3
M
ANUAL
M
ODE
1.
Turn on ST-101
2.
Press
FREQ
and select frequency using section length information
3.
Set receiver to the selected frequency
4.
Press
F1
START
5.
Connect the clips to the pair(s)
6.
Press
F1
START
7.
Use the receiver to check for tone on the cable, adjust receiver gain
8.
Press
LEVEL
and adjust the power output
LEVEL
if needed
9.
Use the receiver instructions to locate the fault