Version 1.0.2
7
Section Length
Frequency
Note
4-10 kFt
335 Hz
Additional fault isolation is
recommended if the section is
greater than 10 kFt. Set the
FREQ
to
335 Hz If the section is longer than
10 kFt,
7.2
AUTO-SET
The preferred and easiest way to start the ST-101 is using the
F3
AUTO-SET
from the Main screen. The ST-
101 will scan the connection and set the initial frequency and PWR LEVEL. The frequency and PWR LEVEL
can then be adjusted if desired.
1.
From the Main screen, press
F3
AUTO-SET
.
2.
The ST-101 prompts to connect the output.
3.
Connect the clips as described in 6.4 above and press
F1
START
.
The ST-101 determines the initial frequency and PWR LEVEL for the current connection.
4.
The ST-
101 displays, “Set SR
-
101 Freq XXX”. This is the initial frequency as determin
ed by the ST-
101. Set the SR-101, or other receiver, to this frequency and press
F1
OK
.
5.
The ST-101 starts transmitting the signal at the frequency and power level determined by the
scan. Follow the instructions for the receiver to ensure the signal is detected by monitoring the
cable.
6.
The frequency can be changed by pressing the
FREQ
key or the power level by pressing the
LEVEL
key as needed. Always ensure the ST-101 and receiver are using the same frequency.
7.
Press
F1 STOP
to temporarily stop transmitting but remain in the Transmit mode. Pressing
F1
START
from the stop screen will resume transmitting.
8.
Press
CLR
to stop transmitting and return to the main screen.
7.3
M
ANUAL
T
RANSMITTING
Use these instructions to transmit a signal at a pre-set frequency.
1.
From the Main screen, press
FREQ
. If the desired frequency is displayed on the main screen, this
step may be skipped.
a.
Use
F1
,
F2
, and
F3
to select and set the desired frequency.
2.
Press
F1 START
3.
The ST-101 prompts to connect the output and press
F1
START.
The ST-101 uses the selected frequency and gradually increases the power level to obtain a
recommended initial
PWR LEVEL
. This level should be sufficient in most cases. The frequency and
gain on the receiver must be adjusted using directions provided with the receiver.
The power LEVEL can be adjusted by the user by pressing the
LEVEL
key from the Transmit screen.
The level may be adjusted up or down, as needed, within the range of 1 to 10.
NOTE: The ST-101 will not transmit signals at power LEVELs that may damage internal circuits.