background image

 

Version 1.0.2 

 

Section Length 

Frequency 

Note 

4-10 kFt 

335 Hz 

Additional fault isolation is 
recommended if the section is 
greater than 10 kFt. Set the 

FREQ

 to  

335 Hz If the section is longer than 
10 kFt, 

7.2

 

AUTO-SET 

The preferred and easiest way to start the ST-101 is using the 

F3

 

AUTO-SET

 from the Main screen. The ST-

101 will scan the connection and set the initial frequency and PWR LEVEL. The frequency and PWR LEVEL 
can then be adjusted if desired. 

1.

 

From the Main screen, press 

F3

 

AUTO-SET

2.

 

The ST-101 prompts to connect the output. 

3.

 

Connect the clips as described in 6.4 above and press 

F1

 

START

The ST-101 determines the initial frequency and PWR LEVEL for the current connection. 

4.

 

The ST-

101 displays, “Set SR

-

101 Freq XXX”. This is the initial frequency as determin

ed by the ST-

101. Set the SR-101, or other receiver, to this frequency and press 

F1

 

OK

5.

 

The ST-101 starts transmitting the signal at the frequency and power level determined by the 
scan.  Follow the instructions for the receiver to ensure the signal is detected by monitoring the 
cable.  

6.

 

The frequency can be changed by pressing the 

FREQ

 key or the power level by pressing the 

LEVEL

 

key as needed. Always ensure the ST-101 and receiver are using the same frequency. 

7.

 

Press 

F1 STOP

 to temporarily stop transmitting but remain in the Transmit mode. Pressing 

F1 

START 

from the stop screen will resume transmitting. 

8.

 

Press 

CLR

 to stop transmitting and return to the main screen. 

7.3

 

M

ANUAL 

T

RANSMITTING

 

Use these instructions to transmit a signal at a pre-set frequency. 

1.

 

From the Main screen, press 

FREQ

. If the desired frequency is displayed on the main screen, this 

step may be skipped. 

a.

 

Use 

F1

F2

, and 

F3

 to select and set the desired frequency.  

2.

 

Press 

F1 START

 

3.

 

The ST-101 prompts to connect the output and press 

F1

 

START.

 

The ST-101 uses the selected frequency and gradually increases the power level to obtain a 
recommended initial 

PWR LEVEL

. This level should be sufficient in most cases. The frequency and 

gain on the receiver must be adjusted using directions provided with the receiver. 

The power LEVEL can be adjusted by the user by pressing the 

LEVEL

 key from the Transmit screen.  

The level may be adjusted up or down, as needed, within the range of 1 to 10. 

NOTE: The ST-101 will not transmit signals at power LEVELs that may damage internal circuits. 

Summary of Contents for ST-101

Page 1: ...ST 101 Signal Transmitter Fault Location Transmitter User Manual Version 1 0 2...

Page 2: ...Allied Analogic Inc 132 Redtail Ct Weatherford TX 76088 817 599 0272 2017 AALogic Inc All rights reserved...

Page 3: ...te 4 5 2 2 Tone Configurations 4 6 Setup 4 6 1 Safety 4 6 2 Fault Pre Testing 4 6 3 Sectioning 5 6 4 Connections 5 6 5 Split Faults 5 7 Transmitting Signals 6 7 1 Frequency selection 6 7 2 AUTO SET 7...

Page 4: ......

Page 5: ...uses the signal to be radiated The highly sensitive receiver tuned to the same frequency as the transmitted signal allows the technician to locate the fault by observing the changes in the signal stre...

Page 6: ...imum frequency and initial power LEVEL The FREQ key allows for frequency selection The LEVEL key is used to adjust the power output LEVEL when transmitting the signal The CFG key allows the user to se...

Page 7: ...output The display is backlight and contrast adjustable by pressing the CFG key A battery charge indicator is in the top left corner Always check this before use If only one segment is shown charge t...

Page 8: ...ay not display the pulsed tone as well when locating a fault 6 SETUP The ST 101 is designed to simplify setup The directions provided with the receiver should be reviewed to ensure the best success in...

Page 9: ...ive fault as follows Fault Description Connections Short Tip connected to Ring Black to Tip and Red to Ring Ground Tip or Ring connected shield Black to sheath and Red to grounded wire Cross Tip or Ri...

Page 10: ...LECTION Pressing the FREQ key allows the user to select a specific frequency The ST 101 displays the recommended distance for each frequency The table below shows the recommendations and notes Section...

Page 11: ...frequency can be changed by pressing the FREQ key or the power level by pressing the LEVEL key as needed Always ensure the ST 101 and receiver are using the same frequency 7 Press F1 STOP to temporar...

Page 12: ...the transmitter operation when the clips have excessively high or low resistances connected to the pair clips 7 4 1 Low Current High Resistance or Open Low current occurs when the resistive fault is t...

Page 13: ...wing table to resolve the error Procedure Solution Check the Clips Ensure the clips and wire are not shorted Measure the fault with a test set The cable pair maybe shorted at the connection point Decr...

Page 14: ......

Page 15: ...e Charge 0 to 45c 32 to 113F Operate 20 to 60c 4 to 158F Storage 20 to 60c 4 to 158F Fault Limits Typical Resistive Fault Limits 1000 ohms Cable Diameter 1 2 3 Short 75K 50K 25K Ground 100K 75K 75K Cr...

Page 16: ......

Page 17: ...r s 4 Press F1 START 5 Set the receiver to the indicated frequency 6 Press F1 OK 7 Use the receiver to check for tone on the cable adjust receiver gain 8 Press LEVEL and adjust the power output level...

Reviews: