20
PulsePak Prime
GDED-IOM-216-B
6.
Once all filters in a column are installed, reinstall the mandrel support
braces over the threaded rod. Tighten the retaining knob on the rods
until the gasket is fully compressed against the back wall.
9.2.8
Installation of accessories
When accessories, such as sprinklers, hopper discharge device(s), and
airlocks, are ordered with the PulsePak Prime, separate installation instructions will
be provided with the collector. For complete information, see the most current
installation drawing or separate IOM.
9.2.9
Electrical
connections
WARNING: Potential shock hazard. Disconnect power before servicing. Only
qualified electrical personnel should work on this system.
The PulsePak Prime pulse-jet cartridge collector is supplied with electrical
solenoids in a NEMA 4 enclosure and the standard pulse controller in a NEMA4X
enclosure. Higher NEMA ratings are available as an option. Do not install in classified
hazardous locations without an enclosure suitably rated for the application and
location.
The standard pulse control supplied with the PulsePak Prime is the DCT-1010
Dust Collector Timer Controller. This pulse controller is used for on-demand or
continuous cleaning applications.