3-8
ATX-Q370A
Fan Out Step Up Time [10]
Determines the amount of time Fan Out takes to increase its value by one
step. Input value range: [0~255]
Fan Out Step Down Time [10]
Determines the amount of time Fan Out takes to decrease its value by one
step in intervals of 0.1 seconds. Input value range: [0~255]
CHA_FAN1 Smart Fan Control [Enabled]
Allows you to enable or disable CHA_FAN1 Smart Fan Control. Configuration
options: [Enabled] [Disabled]
The following sub-items appear only when you set
CHA_FAN1 Smart Fan
Control
to [Enabled].
Fan Control Mode [SMART FAN IV Mode]
Configuration options: [Manual Mode] [Thermal Cruise Mode] [SMART FAN
IV Mode]
The following items appear only when you set
Fan Control Mode
to [Manual
Mode].
PWM/DC Voltage Output [255]
This item appears only when you set the previous item to [Manual Mode] and
allows you to set the voltage allocated for Fan Control. Input value range:
[0~255]
The following items appear only when you set
Fan Control Mode
to [Thermal
Cruise Mode].
Target Temperature [50]
Input value range: [0~127]
Tolerance of Temperature [0]
Input value range: [0~7]
Fan Out Start-Up Value [127]
Input value range: [0~255]
Fan Stop Duty [To Fan Out Stop Value]
Selects fan stop duty mode. Configuration options: [Down to 0] [To Fan Out
Stop Value]