Document number
205065
Version
Rev. N
Issue date
2019-02-04
Sirius OBC and TCM User Manual
Page
166
of
174
10.7.4. Transfer Frame Data Field
The Transfer Frame Data Field contains an integral number of octets of data formatted as
TM Packets, see. The length of this field is fixed, but can be different for different
configurations depending on inclusion of OCF and FECF. The maximum length of this field
is 1109 octets (1115
–
6), and the minimum length is 1103 octets (1115
–
6 - 4 -2)
10.7.5. Operational control field
The Operational Control Field contains a Command Link Control Word
Figure 10.9 Command Link Control Word
Table 10-7 Command Link Control Word
Field
Description
Comment
CONTROL WORD TYPE
Is set to ‘0’
CLCW VERSION NUMBER
Is set to ‘00’
STATUS FIELD
Can be used for Mission-specific
status
No specific setting by TCM-S
COP IN EFFECT
Set to ‘01’
VIRTUAL CHANNEL
IDENTIFICATION
Virtual Channel Identifier
RESERVED SPARE
Set to ‘00’
NO RF AVAIL
Set to ‘0’ if Physical Layer
Available.
Set to ‘1’ if Physical Layer is not
available.
NO BIT LOCK
Set to ‘0’ when bit lock has been
achieved.
Set to ‘1’
when bit lock has not
been achieved.