background image

SP Series 

Operating Manual

register your product at 

a2zozone.com/pages/warranty

Summary of Contents for SP Series

Page 1: ...SP Series OperatingManual register your product at a2zozone com pages warranty...

Page 2: ...tents Important Safety Information 2 Technical Specifications 3 SP Series Features 4 Installation Instructions 6 Operating Instructions 11 Schematic Diagrams 13 Maintenance 17 Troubleshooting 19 FAQ 2...

Page 3: ...etween 40 and 100 degrees Fahrenheit 4 5 to 38 degrees Celsius If the equipment is installed in an environment with temperatures over 100 degrees Fahrenheit additional air cooling must be provided Ins...

Page 4: ...ool operating manual 3 Flexible tubing 4 PTFE tubing 5 Spare fuse 6 Check valve 2 7 Spare fan filter Model Ozone Output g h Electric Power Watts Size Inches Weight lbs SP 3G 3 220 240 OR 110 120 VAC 5...

Page 5: ...the unit If the power is supplied the light will remain a solid red 3 Power Switch Used to power the unit on and off 4 Ozone Concentration Knob Controls the percentage of ozone produced by the unit 5...

Page 6: ...5 A2Z Ozone Inc OZONE ON OFF AMP FLOW METER OZONE CONCENTRATION POWER www A2Zozone com USA 0 10 20 30 40 50 60 70 80 90 100 A 0 0 2 0 4 0 6 0 8 1 1 2 3 4 5 6...

Page 7: ...tal tubing 1 Ozone Out Port Ozone is sucked out and injected into the water 2 Main Fuse If the unit has no power check here first 3 Air Oxygen In Port This sucks in air for the unit to produce ozone P...

Page 8: ...e ozonator Situate the unit in a manner suitable for convenient electrical access Mounting holes are located on the back of the ozone generator for convenient wall mounting mounting hardware is not pr...

Page 9: ...turi Injector Manifold Install the venturi injector with a bypass valve on the water return pipeline The arrow on the venturi injector manifold MUST be set as the same direction as the water flow Turn...

Page 10: ...e ozone generator will be used where water is present a ground fault circuit interrupter must protect the circuit Tube Connection and Start Up Connect a silicone tube if using an oxygen generator oxyg...

Page 11: ...g your finger on the venturi injector opening A small suction should be felt at this injector opening This is what is needed to get the ozone production out of the SP unit and injected into the pool s...

Page 12: ...ecommended that an in ground pool be drained in the winter or after the first rain of a season Use a shock treatment instead of draining to avoid the possibility of severe damage resulting from floati...

Page 13: ...wait a few days to give the ozone and filter system time to work Algae Always maintain the recommended residual levels of bromine or chlorine at least 1 0 PPM to help control algae formation Brushing...

Page 14: ...Schematic Diagrams INJECTOR MANIFOLD Figure 1 1 SP SERIES OZONE OUT OZONE TO INJECTOR MANIFOLD OXYGEN IN CHECK VALVE WATER IN VENTURI BY PASS VALVE WATER OUT 13...

Page 15: ...ut connector Attach 1 5m silicone tube Connect ozone generator to timer switch on pool pump Non return valve arrow points towards venturi Venturi Injector Arrow must point in flow direction Hartford L...

Page 16: ...s Swimming Pool Ozone to injector manifold Pool Filtration and Pump Air Filter Air Input Venturi Injector Manifold NOTE SP UNIT AND OZONE LINE SHOULD BE ABOVE WATER TANK LEVEL THIS PREVENTS WATER BACK...

Page 17: ...Attach Ozone Line Do not block lower half GAUGE gauge to check vaccum vacuum 2 to 3 PSI 0 14 to 0 21 bars Injector Manifold with Check Valve Figure 2 16...

Page 18: ...ool Filter Ozone will keep the water much cleaner than any other type of water purification system This is due to the fact that ozone neutralizes body oils and soaps After ozone kills the bacteria the...

Page 19: ...zone generator The PTFE ozone delivery line s should be inspected daily to ensure water is not flowing back into the ozone generator Check valves should be replaced yearly NOTE The only time it is pos...

Page 20: ...e Check the main fuse change if needed It is a 3 AMP for SP 3G to SP 8G and 6 AMP for the SP 16G fuse Check the tubing inside the machine for kinks If the machine can produce some air but the air is n...

Page 21: ...many contaminants that bromine cannot However ozone only lasts in pool water for a short period of time 15 30 minutes therefore in order to provide lasting protection during times when ozone is not b...

Page 22: ...ion reduces every 30 minutes as follows 8 4 2 1 etc In practice the half life is shorter because a lot of factors can influence the half life Factors are temperature pH concentration and sort solutes...

Page 23: ...of 12 hours each day We recommend that you run your pump for 24 hours a day in the summer Up to 80 of the water treatment is done by your filter so don t be afraid to use it The extra electricity cos...

Page 24: ...d or sodium bicarbonate 80 100ppm Maintain pH 7 2 to 7 8 HCL acid to lower and sodium bicarbonate to increase Shock treat with hydrogen peroxide 35 100mL 1000 Liters pool water Keep pool clear of leav...

Page 25: ...r important advantages include reduced pool maintenance and reduced exposure to toxic chemicals in storing handling and swimming Will my ozone generator help the ozone layer Ozone from a swimming pool...

Page 26: ...NY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE AND SUCH WARRANTIES ARE HEREBY DISCLAIMED AND e A2Z Ozone SHALL NOT BE LIABLE UNDER ANY CIRCUMSTANCES FOR L...

Page 27: ..._______________________State_________Zip__________ Phone ____ ________________ Dealer Info Dealer Name______________________________ Dealer Address_____________________________________________________...