background image

8

Main Power

•  Use the power cable provided to connect the SP-5G (110V) Ozone Generator to a properly 

rated and grounded receptacle. 

•  A ground fault circuit interrupter must protect the circuit if the ozone generator will be 

used where water is present.

Tube Connection and Start Up

•  Connect a silicone tube (if using an oxygen generator, oxygen tank or external air 

compressor) to the SP-5G (110V) Ozone Generator (Air In). This will serve as oxygen or air 
for ozone production. (2-4 LPM @ 2 PSI maximum.)

•  Connect the ozone generator PTFE tube (Ozone Out) to the  application processor.
•  Install a check valve 10 inches after the ozone outlet tube fitting. Install the check valve 

by cutting the tube ten inches after ozone out fitting. Next, connect both ends of the cut 
tubes to the check valve. Please direct the arrow on the check valve in the direction of 
the application. NOTE: The  venturi injector has an internal check valve to help prevent 
backflow.

•  Make sure there is a vacuum (or that there is suction) at the  opening via a gauge or test 

it by putting your finger on the  opening. 

•  There will be a small suction at this opening. The suction will move the ozone out of the 

SP-5G (110V) Ozone Generator and inject it into the piping system. 

•  Check that the flow meter indicates that the air flow is at least 2-4 LPM. 
•  Now connect the PTFE tube from the venturi injector to the ozone generator.
•  Turn on the power on the external panel of the ozone generator.
•  The ozone indicator light should illuminate and the unit’s fan should turn on.
•  Increase power to the cells by turning the ozone control knob clockwise. 

Summary of Contents for SP-5G

Page 1: ...Distributed by A2Z Ozone Inc 1844 Cargo Court Louisville KY 40299 USA 1 502 499 4977 EPA Est 95432 KY 1 Active Ingredient Ozone Warning Do Not Inhale Ozone Keep Out of Reach of Children Produced by Bl...

Page 2: ...lled must be well ventilated in case of accidental leakage This unit does not contain ozone This unit produces ozone while running by creating oxygen in the air or an oxygen source to ozone Use a dega...

Page 3: ...y for this product must include a suitably rated switch or circuit breaker to open all ungrounded supply conductors Keep ambient temperature around the equipment between 40 and 100 Fahrenheit 4 5 to 3...

Page 4: ...ngs Items Included SP 5G 110V Ozone Generator SP 5G 110V operating manual Flexible tubing for oxygen supply PTFE tubing for ozone Spare fuse Check valve x2 Spare fan filter Note The SP 5G 110V Ozone G...

Page 5: ...the unit If the power is supplied the LED will illuminate 3 Power Switch Used to power the unit on and off 4 Ozone Concentration Knob Controls the percentage of ozone produced by the unit 5 AMP Meter...

Page 6: ...5 1 2 3 4 5 6...

Page 7: ...e If the unit has no power check here first 3 Air Oxygen In Port This sucks in air for the unit to produce ozone Please do not block this intake port Optional oxygen intake or air pump connection 4 Po...

Page 8: ...uri vacuum or system gravity will cause backflow to travel down the ozone output tube and enter into the ozone generator Situate the SP 5G 110V Ozone Generator in a manner suitable for convenient elec...

Page 9: ...after ozone out fitting Next connect both ends of the cut tubes to the check valve Please direct the arrow on the check valve in the direction of the application NOTE The venturi injector has an inter...

Page 10: ...NOTE In a clean environment perform the cleaning procedure every three months Turn the SP 5G 110V Ozone Generator off Clean the filter screen with soap and water Rinse Dry the filter with a clean towe...

Page 11: ...low into the ozone generator Inspect the PTFE ozone delivery line daily to ensure water is not flowing back into the ozone generator Replace check valves every 6 months to a year of use NOTE The only...

Page 12: ...1 to 2 hours to dry the ozone tube Check the main fuse Change it if needed It is a 3 AMP for this unit Check the tubing inside the machine for kinks If the machine can produce some air but the air is...

Page 13: ...ANY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE AND SUCH WARRANTIES ARE HEREBY DISCLAIMED AND e A2Z Ozone SHALL NOT BE LIABLE UNDER ANY CIRCUMSTANCES FOR...

Page 14: ..._____________State_________Zip__________ Phone ____ ________________ Dealer Info Dealer Name______________________________ Dealer Address_______________________________________________________ City___...

Reviews: