background image

Troubleshooting

The test method for failure of the ozone generator:

•  Check the power input for correct voltage (110V)
•  If the ozone generator is on, but not producing ozone, then the SP-5G (110V) Ozone 

Generator is overheating or there is water back flow to the ozone generator. 

•  Turn off the ozone generator and let the air flow through the unit for 1 to 2 hours to dry 

the ozone tube. 

•  Check the main fuse. Change it if needed. It is a 3 AMP for this unit. 
•  Check the tubing inside the machine for kinks.
•  If the machine can produce some air, but the air is not ozone; please check the following:

•  The power indication lamp is lit.
•  Check the ozone control knob is set above zero.
•  Check the ozone board fuse.
•  Check the wire from terminal to ozone board.
•  Check that the potentiometer wire is connected to the ozone board.

If you are still experiencing problems, please contact A2Z Ozone at 1+ (502) 499-4977. 

11

Summary of Contents for SP-5G

Page 1: ...Distributed by A2Z Ozone Inc 1844 Cargo Court Louisville KY 40299 USA 1 502 499 4977 EPA Est 95432 KY 1 Active Ingredient Ozone Warning Do Not Inhale Ozone Keep Out of Reach of Children Produced by Bl...

Page 2: ...lled must be well ventilated in case of accidental leakage This unit does not contain ozone This unit produces ozone while running by creating oxygen in the air or an oxygen source to ozone Use a dega...

Page 3: ...y for this product must include a suitably rated switch or circuit breaker to open all ungrounded supply conductors Keep ambient temperature around the equipment between 40 and 100 Fahrenheit 4 5 to 3...

Page 4: ...ngs Items Included SP 5G 110V Ozone Generator SP 5G 110V operating manual Flexible tubing for oxygen supply PTFE tubing for ozone Spare fuse Check valve x2 Spare fan filter Note The SP 5G 110V Ozone G...

Page 5: ...the unit If the power is supplied the LED will illuminate 3 Power Switch Used to power the unit on and off 4 Ozone Concentration Knob Controls the percentage of ozone produced by the unit 5 AMP Meter...

Page 6: ...5 1 2 3 4 5 6...

Page 7: ...e If the unit has no power check here first 3 Air Oxygen In Port This sucks in air for the unit to produce ozone Please do not block this intake port Optional oxygen intake or air pump connection 4 Po...

Page 8: ...uri vacuum or system gravity will cause backflow to travel down the ozone output tube and enter into the ozone generator Situate the SP 5G 110V Ozone Generator in a manner suitable for convenient elec...

Page 9: ...after ozone out fitting Next connect both ends of the cut tubes to the check valve Please direct the arrow on the check valve in the direction of the application NOTE The venturi injector has an inter...

Page 10: ...NOTE In a clean environment perform the cleaning procedure every three months Turn the SP 5G 110V Ozone Generator off Clean the filter screen with soap and water Rinse Dry the filter with a clean towe...

Page 11: ...low into the ozone generator Inspect the PTFE ozone delivery line daily to ensure water is not flowing back into the ozone generator Replace check valves every 6 months to a year of use NOTE The only...

Page 12: ...1 to 2 hours to dry the ozone tube Check the main fuse Change it if needed It is a 3 AMP for this unit Check the tubing inside the machine for kinks If the machine can produce some air but the air is...

Page 13: ...ANY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE AND SUCH WARRANTIES ARE HEREBY DISCLAIMED AND e A2Z Ozone SHALL NOT BE LIABLE UNDER ANY CIRCUMSTANCES FOR...

Page 14: ..._____________State_________Zip__________ Phone ____ ________________ Dealer Info Dealer Name______________________________ Dealer Address_______________________________________________________ City___...

Reviews: