background image

2

Important Safety Information

READ AND FOLLOW ALL INSTRUCTIONS

•  Read this manual completely before attempting installation and/or operation.
•  Install in accordance with the installation instructions.
•  Connect to a grounded, grounding type receptacle only.
•  Follow all applicable electrical codes.
•  To avoid electric shock, be sure to turn power OFF and disconnect from power source 

before any service work is performed. Failure to do so could result in serious injury or 
death. Have a licensed electrician make all electrical connections. Replace damaged 
electrical cables immediately.

•  Install the ozone generator at least five feet from water using nonmetallic plumbing. 
•  The SP-5G must be mounted indoors or under a cover for protection from the elements. 
•  Install check valves to prevent water from coming into contact with the electrical equipment. 
•  The electrical supply for this product must include a suitably rated switch or circuit breaker 

to open all ungrounded supply conductors.

•  Keep ambient temperature around the equipment between 40° and 100°  Fahrenheit 

(4.5° to 38° Celsius). If installing the equipment in an environment with temperatures over 
100° Fahrenheit, provide additional air cooling. Installation without additional air cooling 
in an environment where temperatures exceed 100° Fahrenheit for any continuous 24-
hour period will void the warranty. 

•  If feeding ozone generator with an oxygen supply, a spontaneous and violent ignition may 

occur if oil, grease or greasy substances come in contact with oxygen under pressure. 
These substances must be kept away from oxygen regulators, cylinder valves, tubing, 
connections, and all other oxygen equipment. 

CAUTION!

In case of accidental leakage, install the ozone generator in a well-ventilated area.
In accordance with California Regulations, this ozone generator is solely for 

industrial use and must be installed by a professional. Potential health hazard: 

emits ozone.

Summary of Contents for SP-5G

Page 1: ...Distributed by A2Z Ozone Inc 1844 Cargo Court Louisville KY 40299 USA 1 502 499 4977 EPA Est 95432 KY 1 Active Ingredient Ozone Warning Do Not Inhale Ozone Keep Out of Reach of Children Produced by Bl...

Page 2: ...lled must be well ventilated in case of accidental leakage This unit does not contain ozone This unit produces ozone while running by creating oxygen in the air or an oxygen source to ozone Use a dega...

Page 3: ...y for this product must include a suitably rated switch or circuit breaker to open all ungrounded supply conductors Keep ambient temperature around the equipment between 40 and 100 Fahrenheit 4 5 to 3...

Page 4: ...ngs Items Included SP 5G 110V Ozone Generator SP 5G 110V operating manual Flexible tubing for oxygen supply PTFE tubing for ozone Spare fuse Check valve x2 Spare fan filter Note The SP 5G 110V Ozone G...

Page 5: ...the unit If the power is supplied the LED will illuminate 3 Power Switch Used to power the unit on and off 4 Ozone Concentration Knob Controls the percentage of ozone produced by the unit 5 AMP Meter...

Page 6: ...5 1 2 3 4 5 6...

Page 7: ...e If the unit has no power check here first 3 Air Oxygen In Port This sucks in air for the unit to produce ozone Please do not block this intake port Optional oxygen intake or air pump connection 4 Po...

Page 8: ...uri vacuum or system gravity will cause backflow to travel down the ozone output tube and enter into the ozone generator Situate the SP 5G 110V Ozone Generator in a manner suitable for convenient elec...

Page 9: ...after ozone out fitting Next connect both ends of the cut tubes to the check valve Please direct the arrow on the check valve in the direction of the application NOTE The venturi injector has an inter...

Page 10: ...NOTE In a clean environment perform the cleaning procedure every three months Turn the SP 5G 110V Ozone Generator off Clean the filter screen with soap and water Rinse Dry the filter with a clean towe...

Page 11: ...low into the ozone generator Inspect the PTFE ozone delivery line daily to ensure water is not flowing back into the ozone generator Replace check valves every 6 months to a year of use NOTE The only...

Page 12: ...1 to 2 hours to dry the ozone tube Check the main fuse Change it if needed It is a 3 AMP for this unit Check the tubing inside the machine for kinks If the machine can produce some air but the air is...

Page 13: ...ANY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE AND SUCH WARRANTIES ARE HEREBY DISCLAIMED AND e A2Z Ozone SHALL NOT BE LIABLE UNDER ANY CIRCUMSTANCES FOR...

Page 14: ..._____________State_________Zip__________ Phone ____ ________________ Dealer Info Dealer Name______________________________ Dealer Address_______________________________________________________ City___...

Reviews: