7
Installation Instructions
Ozone Generator Placement
• Install ozone generator in a clean, dry area with good ventilation.
• Place the MP-1000 (110V) Ozone Generator above any water tank level.
• If pressure is lost in the venturi injector vacuum and the unit is below water tank level, gravity
will cause water to travel down the ozone output hose and enter into the ozone generator.
• Place stone no more than 12 inches deep for the MP-1000.
NOTE:
Place the ozone generator in room temperatures below 130° F , 54 ° C. Prolonged exposure
to extreme temperatures will void the warranty.
Venturi Injector Installation
• Install the venturi injector with the bypass valve on water recirculation pipeline.
• Set the arrow on venturi injector in the same direction as water flow.
• Turn water pump on and close the bypass valve until a vacuum is created at the venturi injector
input.
NOTE:
Use a gauge to check vacuum -2 to -3 PSI (-0.14 to -0.21 bars) or place finger over end of
venturi injector valve to feel the vacuum. At this point, the air is injected into the water line. This
can be observed as air bubbles inside the water tank.
NOTE:
The water tank requires an exhaust to the outside of the building
with an ozone destructor to remove excessive ozone.
Main Power
• Use the power cable provided to connect the MP-1000 to a properly rated and grounded
receptacle.
• If the MP-1000 will be used where water is present, a
ground fault circuit interrupter must protect the circuit.
• Plug your power cord into the back of the unit and the wall socket.
Summary of Contents for MP-1000
Page 6: ...5 1 2 3 4 5 6 7 8 9 MP 1000...
Page 14: ...13 1 2 3...