background image

12

Troubleshooting

Problem

Possible Cause

What to Do

No Ozone

(Ozone LED is not 

illuminated, but pump

 is working) 

Bad ozone board

Normally the fuse on the back of the unit 
will blow or the ozone light won’t light up. 
Contact us for a replacement board.

No air flow

Make sure the air loop is in the correct 
position if using ambient air. Make sure 

O

2

 

generator is functioning and 

O

2

 is flowing. 

Broken ozone switch

If the ozone power switch is broken then 
there won’t be power to the exhaust fan 
and ozone board.
 

Contact us

 for a replacement.

No Power

Check fuses

There are two fuses. Usually the back 
rocker will blow. The other fuse is on the 
ozone board.

Check the timer knob

If the timer knob isn’t engaged then the 
unit won’t power on.

Back switch

If there is no power entering the unit then 
there is something wrong with the back 
rocker switch.

No Ozone

Broken fuse

Check the fuse on the ozone board. Ensure 
this is the correct AMP (see chart on pg 
15)

Internal Air Pump 

Not Working

Bad air pump switch Replace air pump switch

Air pump does 

not work

Replace air pump

Summary of Contents for MP-1000

Page 1: ...and Distributed by A2Z Ozone Inc 1844 Cargo Court Louisville KY 40299 USA 1 502 499 4977 EPA Est 95432 KY 1 Active Ingredient Ozone Warning Do Not Inhale Ozone Keep Out of Reach of Children Produced b...

Page 2: ...NING The use of a degasifier and an ozone destructor is necessary to ensure excessive ozone is safely removed from the application Leave the area while the application is in operation In case of accid...

Page 3: ...grounded receptacle If the MP 1000 will be used where water is present a ground fault circuit interrupter must protect the circuit PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE Use ozone test s...

Page 4: ...g hr LPM H x W x D V W mg L lbs KG MP 1000 0 053 1 1 LPM of O2 or dry air 10 7 x 6 x 9 110V 45 16 7 1 5 LPM w O2 input 2 w internal pump 8 5 4 Items Included MP 1000 110V ozone generator MP 1000 110V...

Page 5: ...t into each MP Series unit If using oxygen supply DO NOT turn on air pump switch 5 O3 Out Port Ozone produced by the unit exits through this port 6 O2 In Port Optional hook up port for an external oxy...

Page 6: ...5 1 2 3 4 5 6 7 8 9 MP 1000...

Page 7: ...e Generator is equipped with timer functions The hourly timer knob can be adjusted between 15 minutes and 4 hours at any time interval between 15 minutes to 4 hours To operate this timer turn the knob...

Page 8: ...ter recirculation pipeline Set the arrow on venturi injector in the same direction as water flow Turn water pump on and close the bypass valve until a vacuum is created at the venturi injector input N...

Page 9: ...ch is in the OFF position when using an oxygen source For Ambient Air Turn on both air compressor switch and the ozone switch in that order Keep in mind the unit will NOT power up until the timer is s...

Page 10: ...d fan should turn on Increasepowertothecellsbyturningtheozoneconcentrationknobclockwise Pleaseremember to make a full rotation clockwise Prior to shutting off the feed gas to the unit turn off the swi...

Page 11: ...Turn ON OFF both the main power and air compressor switch located on the front panel To power down flip the ozone switch and wait 30 seconds Then flip the air pump switch Using External Air Compresso...

Page 12: ...Remove the back fan guard and screen To do this pull out the corner Clean sponge screen with soap and water Rinse Dry sponge screen thoroughly with a clean towel Reinstall the screen and fan guard Plu...

Page 13: ...witch is broken then there won t be power to the exhaust fan and ozone board Contact us for a replacement No Power Check fuses There are two fuses Usually the back rocker will blow The other fuse is o...

Page 14: ...13 1 2 3...

Page 15: ...ard Check the air compressor line or oxygen input If the generator is taking in oxygen please check the tube inside the machine for kinks If the machine can produce some air but the air is not ozone p...

Page 16: ...s d ANY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR PARTICULAR PURPOSE AND SUCH WARRANTIES ARE HEREBY DISCLAIMED AND e A2Z Ozone SHALL NOT BE LIABLE UNDER ANY CIRCUMSTANCES...

Page 17: ..._______________State_________Zip__________ Phone ____ ________________ Dealer Info Dealer Name______________________________ Dealer Address_______________________________________________________ City_...

Reviews: