8
Using Oxygen Air:
The ‘Oxygen In’ port on the side of unit can be hooked up to an oxygen tank or oxygen generator
of your choosing. Keep in mind, to hook up an oxygen tank or oxygen generator you will need a
regulator that will reach 1 LPM at 2 PSI
To connect an oxygen tank to Aqua-8 follow these steps:
• First, you will connect one end of tubing to your oxygen tank (or concentrator) and then attach
the other onto the right side of the Aqua-8.
• You will then need to set your regulator to a maximum of 1 LPM or 2 PSI.
• Once the regulator is set you can turn on the oxygen flow and let it run for 10 seconds.
• After the 10 seconds is up, turn on your Aqua-8 to appropriate timer function.
• Once the timer function has completed, you will need to let the oxygen run for another 5
seconds to clear the remaining ozone from the ozone tube.
• After 5 seconds, you can turn off the oxygen flow.
Note: If attaching an oxygen tank/generator, the input should not exceed 2 PSI and 1 LPM. If this
amount is exceeded, the unit will be damaged.
Summary of Contents for Aqua-8
Page 5: ...4 9 1 7 10 2 3 4 5 6 8...