Aqua-8 Features
1
Plus (+) Button
Use to select desired function setting from the Timer Function table.
2
LED Screen
Displays function setting selected and operation time remaining after
the Aqua-8 begins producing ozone. The ozone production will start
10 seconds after the selection is made on the LED.
3
Pump Light
A blue light indicates when the unit pump is running.
A red light indicates pump is not working.
4
Ozone Light
Indicates when the unit is running. When it is in operation, the
light will remain a solid blue. A red light indicates no ozone is being
produced.
5
Fan Light
A blue light indicates when the unit fan is running.
A red light indicates the fan is not working.
6
Pause Button
Use to pause the unit when it is in operation. The LED screen will
hold the previously selected function and the time remaining until
the Pause Button is pressed again.
7
Power Button
Use to turn the unit on and off.
8
Minus (-) Button
Use to select desired function setting from the Timer Function table.
9
Ozone Outlet
Where the tubing is attached to the unit. One end of the ozone supply
tubing is attached to the ozone outlet on the Aqua-8 unit, while the
other end is attached to a diffuser stone.
10
Oxygen Inlet
DO NOT CONNECT OZONE TUBE TO OXYGEN INLET.
Optional hookup port for an external oxygen source. This can be
used to produce a more pure ozone. The oxygen regulator should be
set at a 1 LPM and 2.5 PSI maximum.
5
Summary of Contents for Aqua-8