8.Bluetooth
8.2 Lithium charging voltage
8.1 Charging voltage wet, gel, AGM battery
page 9
02/2022
float voltage
boost
With the help of the app, you can set the parameters, including the devices and battery
parameters. The operating status of the control unit is also displayed in real time.
default
charging voltage
For detailed instructions, please read the instructions in the Bluetooth app.
equalizing charge
With the charging voltages wet, gel or AGM battery, you must set the parameters for boost,
equalization and float voltage via the app.
14.0-15.0V
Overcharge Recovery Voltage + 1.5V>Lithium
Overcharge Protection Voltage > Overcharge Recovery Voltage + 0.2V.
You can set the overcharge protection and overcharge recovery voltage of the lithium
battery through the app. Overcharge Protection (CVT): 10.0-17.0V Overcharge
Recovery Voltage (CVR): 9.0-16.8V
14.0-14.8V
charge level
14.5V
The following voltage parameters apply to 25°C/12V systems:
13.0-14.5V
If the deviation is greater than 0.2V, the manufacturer assumes no liability for a
system malfunction caused by this.
charging voltage
The controller has a Bluetooth communication function. After successfully installing the app,
the controller can be connected to the mobile phone via Bluetooth.
13.7V
14.8V
area of
operation manual
MPPT solar charge controller X45/10
Machine Translated by Google