background image

operation  manual

MPPT  solar  charge  controller  X45/10

If  you  have  any  questions,  please  do  not  hesitate  to  contact  us!

a-TronlX  MPPT  solar  charge  controller  X45/10

Item  No.  9887579

panel  parameters

battery  parameters

Load

system  parameters

page  16

02/2022

Verbindungsweg  23  25469  Halstenbek /  Hamburg  GERMANY  
Telephone  +49  4101  |  3  76  76-0 /  [email protected] /  www.akkusys.de

AKKU  SYS  Accumulator  and  Battery  Technology  North  GmbH

0-30  min  (programmable,  default:  0  min)

(Default:  Always  On)

10m

Charging  voltage  

target  9.2–16.8V  (programmable)

Day/Night  Delay  Time

ownconsumption

degree  of  protection

IP67

Maximum  voltage  at  the  PV  connection

(battery  voltage  +1.0V)  -Voc*0.9  *1

Maximum  charge  conversion

ambient  temperature

lithium

45V

output  current

8mA

4,000m

Turn  on  low  voltage  again  9.6–16.0V  (programmable)

Maximum  tracking  efficiency

96.50%

Always  on,  Dusk,  Five  levels,  Manual

0-100%RH

communication  distance

ambient  humidity

Restore  charge  voltage  Turn  off  

lithium  low  voltage  9.0–15.0V  (programmable)

size

Maximum  input  power

10A

MPPT  tracking  area

working  mode

Weight

Maximum  height

10.0–17.0V  (programmable)

Dusk/twilight  detection  in  V

>99.9%

*2  VOC  is  the  open  circuit  voltage  of  the  solar  panel.

3.0~8.0V  (default:  5.0V)

85.8*81*23.1mm  

260g  -35~+60°C

*1  The  VOC  of  the  solar  panel  must  not  exceed  this  value,  otherwise  the  controller  will  be  damaged.

Yes,  No,  Slow  (Lithium,  Default:  Yes)  0°C  

Load  protection

130W

Machine Translated by Google

Summary of Contents for X45/10

Page 1: ...Installation and Operating instructions a TroniX MPPT solar charge controller X45 10 02 2022 page 1 9887579 model item number a Tronix MPPT solar charge controller X45 10...

Page 2: ...ord GmbH cannot be held responsible for any inaccuracies or inappropriate information in these operating instructions We reserve the right to make design and device changes that serve to improve the p...

Page 3: ...f Test 9 10 LED indicator 12 12 7 6 Commissioning of the controller 8th 8 1 Charging Voltage Wet Gel AGM 9 Loading modes 9 15 5 8 4 Low Voltage Reclosing LVR 8 5 0 C Charge Lithium 9 4 Manual operatio...

Page 4: ...es are identified by the appropriate symbols pictograms and must be observed otherwise they will be lost Danger high voltage ENVIRONMENT Make use of the certified and professional recycling service of...

Page 5: ...relevant laws Otherwise personal injury or equipment damage may occur The solar charge controller may only be used in photovoltaic systems that comply with these operating instructions Likewise only...

Page 6: ...e Maximum Power Point Tracking MPPT technology Automatic activation of the BMS when due to LVD 5 level load output timer Robust and durable aluminum housing High charge conversion efficiency of up to...

Page 7: ...th the Make sure the cable lengths between the battery and the controller are as short as possible Make sure that the cable cross section is sufficient and that you connect it in the correct order The...

Page 8: ...in the App Store iOS For detailed explanations and settings please read the user manual of the Bluetooth app Apple It then automatically switches to normal operation If the controller is set to gel w...

Page 9: ...Voltage 1 5V Lithium Overcharge Protection Voltage Overcharge Recovery Voltage 0 2V You can set the overcharge protection and overcharge recovery voltage of the lithium battery through the app Overch...

Page 10: ...1 4 to 12 8 V SoC SoC 3 If you want to change the LVD you must first change the LVR The low voltage protection of the controller can be divided into two types a Battery voltage control Low voltage cut...

Page 11: ...open circuit voltage of the solar system the charge controller recognizes day and night The day night threshold can be adjusted depending on the lighting conditions Battery cannot be charged The load...

Page 12: ...stem then takes at time 4 the data from time 5 and previous data about the time of sunrise With this charging mode the day night threshold values and the day night delay can be set The load can be swi...

Page 13: ...ion Equal or reinforced charge Overvoltage protection Fast flashing 0 1 0 1s The output power is 0 LEDs Slow blinking 0 5 2s Charging Works normally If the controller turns off the load due to under v...

Page 14: ...is probably damaged Check battery performance and battery fuse Battery not charging links remedy Charge battery via LVR The controller turns off the system until the temperature falls below 60 C at th...

Page 15: ...per cell boost equalization 3 33mV K per cell float Protected Protected MPPT charge voltage and Lithium Wet Gel AGM Default Gel 15 5V Protected 1 countercurrent Turns off immediately 1 Controller can...

Page 16: ...the PV connection battery voltage 1 0V Voc 0 9 1 Maximum charge conversion ambient temperature lithium 45V output current 8mA 4 000m Turn on low voltage again 9 6 16 0V programmable Maximum tracking...