Installation and Operating Instructions 
UPS Edition One 1kVA, 2kVA, 3kVA

Table of Contents

 Page 

1. Important Safety Warning 

4

1.1 Symbols used in this guide 

5

1.2 Transportation 

5

1.3 Preparation 

5

1.4 Installation 

5

1.5 Operation 

7

1.6 Maintenance, service and faults 

7

1.7 Handling of batteries 

8

2. Installation and setup

 9

2.1 Unpack checking 

9

2.2 Device view 

9

2.3 Setup the UaPS 

12

2.4 UPS start up and turn off 

14

3. Operations

 19

3.1 Button operation 

19

3.2 LCD display 

20

3.3 UPS setting 

22

3.4 Operational Status and Mode(s) 

25

3.5 Alarm or Fault reference code 

25

4. Troubleshooting

 26

5. Storage and Maintenance

 27

6. Options

 28

7. Specification

 31

Summary of Contents for UPS Edition One 1kVA

Page 1: ...ing Instructions a TroniX UPS Edition One 1kVA 2kVA 3kVA Model Capacity VA Article number a TroniX UPS Edition One 1kVA 1000 9884900 a TroniX UPS Edition One 2kVA 2000 9885105 a TroniX UPS Edition One...

Page 2: ...and network functions it meets the world s most advanced level With the a Tronix Series Edition One your installations are safely protected from power supply problems and the functionality of your equ...

Page 3: ...Operation 7 1 6 Maintenance service and faults 7 1 7 Handling of batteries 8 2 Installation and setup 9 2 1 Unpack checking 9 2 2 Device view 9 2 3 Setup the UaPS 12 2 4 UPS start up and turn off 14 3...

Page 4: ...nding laws during installation operation and maintenance otherwise personal injury or damage to the equipment may occur The safety instructions in this manual serve as a supplement to the local safety...

Page 5: ...bols pictograms and must be observed WARNING Warning of dangerous electrical voltage General warning of danger points Warning when handling accumulators NOTE This symbol indicates texts notes or tips...

Page 6: ...ment 1 4 Installation To avoid electrical hazards the UPS should only be connected in a de energised state Do not connect any loads to the UPS that could overload the unit Lay cables so that no one ca...

Page 7: ...iliar with accumulators and the necessary precautions may replace accumulators and supervise the work Unauthorised persons must be kept away from the accumulators Caution risk of electric shock Accumu...

Page 8: ...dispose of the batteries by burning them There is a risk of explosion Do not open or destroy any batteries The released electrolyte can cause injuries to the skin and eyes caustic hazard It is toxic a...

Page 9: ...age is detected Please contact the dealer immediately Check the accessories against the packing list and contact the dealer if any parts are missing Accessories include UPS user manual software suite...

Page 10: ...Page 10 09 2021 Installation and Operating Instructions UPS Edition One 1kVA 2kVA 3kVA Front view Example Edition One 1kVA Example Edition One 2kVA...

Page 11: ...1kVA Example Edition One 2kVA Edition One 1kVA 2kVA 3kVA 1 EPO connection EMERGENCY POWER OFF 2 Expansion module slot Intelligent Slot 3 External battery bank connection 4 Load connection UPS output...

Page 12: ...use of extension cables For models with 208 220 230 240VAC The mains cable is included with the UPS Step 3 UPS output connection For earthed type outlets you can simply plug the power supplies of you...

Page 13: ...USB port and RS 232 port can t work at the same time Step 5 Turn on the UPS Press the ON button on the front panel for two seconds to power on the UPS NOTE The battery charges fully during the first f...

Page 14: ...s do not exceed the UPS capacity to prevent an overload alarm a Once mains power is plugged in the UPS will charge the battery at the moment the LCD shows that the output voltage is 220 which means th...

Page 15: ...more than half a second to turn off the UPS b When turning off the UPS it will do self testing firstly The LEDs light and go out circularly and orderly until there is no display on the cover Operatio...

Page 16: ...ine UPS LCD display 3 Function keys LED Indicator Indicator Description On The UPS has an active alarm or fault Red The UPS is in Bypass mode On The UPS is operating normally onbypassduring High Effic...

Page 17: ...mode without save UP To turn off the ups or exit setting mode without save DOWN To go ton ext selection ENTER ON To turn on the ups or confirm the selection in setting mode or enter setting mode LCD...

Page 18: ...n line mode In AC mode it will present battery charging status Status Battery capacity LCD Display 0 24 4 bars will flash in turns Constant 25 49 Bottom bar will be on and the other three bars will fl...

Page 19: ...ress and hold this button it will switch to normal mode Turn off the UPS Press and hold this button at least 2 seconds to turn off the UPS in battery mode UPS will be in standby mode under power norma...

Page 20: ...UPS Edition One 1kVA 2kVA 3kVA 3 2 LCD display There are 8 interfaces available in the LCD display Item Interface Description Content Displayed 01 Input voltage Output voltage 02 Input frequency Outp...

Page 21: ...g Instructions UPS Edition One 1kVA 2kVA 3kVA Item Interface Description Content Displayed 05 Environment Temperature 06 UPS model 07 Firmware Version 08 Alarm Code Warming Message All alarm codes are...

Page 22: ...nt Or for choosing different pages After the UPS turn ON press buttons for 5 seconds and then goes into the setting interface page NOTE To exit the setting mode and confirm your selection press the DO...

Page 23: ...to change the setting 50 oder 60 Hz 03 Press UP button to select the previous setting Press DOWN button to select the next setting Battery capacity setting Press Enter button to change the setting Bat...

Page 24: ...ypass voltage lower limit setting Press Enter button to change the setting The bypass voltage lower 07 limit range is 170 220 Vac Press UP button to select the previous setting Press DOWN button to se...

Page 25: ...ce Beep continuously Fault LED lit 18 Soft start failed Beep continuously Fault LED lit 19 Rectification model Over Temperature Twice per second Fault LED lit 20 Inverter model Over Temperature Twice...

Page 26: ...o high or the charger is fault Contact your dealer Alarm code is shown as 34 and battery led blinking Battery voltage is too low or the charger is fault Contact your dealer Alarm code is shown as 32 a...

Page 27: ...t us on the order hotline 49 4101 376760 at info akkusys de or use the QR code Be sure to return the used battery in the replacement battery packaging to a recycling centre or send it to your dealer D...

Page 28: ...the two screws on each side of the card Carefully insert the SNMP card and secure the screws Relaycard The internal mini relay card is used as an interface for UPS peripheral monitoring The contact si...

Page 29: ...hem again and switch on the UPS manually The maximum resistance in the shorted loop is 10 ohms Always test the EPO function before applying your critical load to avoid accidental loss of load Leave th...

Page 30: ...used either as the sole energy storage device or as a supplement to the internal battery bank in order to achieve an extension of the autonomy time and or to adapt to the required load conditions Due...

Page 31: ...C 24 48 72 Standard battery pcs x Ah not included 2 x 9 4 x 9 6 x 9 Charging current max Default 1 Output Voltage V AC 208 220 230 240 Frequency Hz Mains mode 46 54Hz oder 56 64Hz Battery mode 50 60 0...

Page 32: ...ik Nord GmbH Verbindungsweg 23 25469 Halstenbek Hamburg GERMANY Tel 49 4101 3 76 76 0 Fax 49 4101 3 76 76 66 info akkusys de www akkusys de Other manufacturers and product ranges you will find in our...

Reviews: