5
DMP801
English
to PC
audio out
audio in
CONNECTION
Connect all necessary input and output devices� Input can be achieved through correctly wired Euroblock connectors�
Balanced Unbalanced
TIP:
Send
PIN 1:
Shield/Ground
PIN 1:
Shield/Ground
Ring:
Receive
PIN 2:
Cold (-)
PIN 2:
Link to PIN 1
Sleeve:
Shield/Ground
PIN 3:
Hot (+)
PIN 3:
Hot (+)
HOW TO SET THE UNIT ID OF IP ADDRESS
When the PIN2 is set to ON, the host bits (unit ID) of the IP address for DMP801 is set manually by user via the 3rd PIN
and the 4th PIN of the DIP switch�
The leading digit is set by the combination of 3rd PIN and the 4th PIN of the 8-PIN DIP switch and the last digit is set by
the rotary switch�
The configurable range for the first digit is
0, 1, 2
and
3.
The configurable range for the last digit is
0, 1, 2, 3, 4, 5, 6, 7, 8, 9, A, B, C, D, E
and
F
�
Euroblock connectors
1/4” TRS Phone Jack
8
7
65
4 3
2 1 0 F E
D C
BA
9
IP address: 192�168� 0�Xx
upper position: ON
Iower position: OFF
8
7
65
4 3
2 1 0 F E
D C
BA
9
Value
The 3rd PIN
The 4th PIN
0
OFF
OFF
1
ON
OFF
2
OFF
ON
3
ON
ON