15
12a
12
13
13e
13d
13
Exchange
the micro switch for the safety guard
in the following way:
a)
Remove the rear part
(1)
, the lid of the mixer
(2)
and the operation
panel
(3)
.
b)
Take off the planetary head pulley
(6D).
c)
Remove the top plate
(13A)
by first removing the four screws
(13B)
and thereafter the screws
(13C)
.
d)
Loosen the screws
(13D)
in both sides. Turn the safety guard into
to horizontal position, and now the safety guard including fittings
(13E)
with micro switch can be lifted up. The micro switch can
now be exchanged.
e)
Screw the new micro switch on to the fittings, and follow the in
-
structions in reverse order.
12
Exchange
the micro switch for bowl lift
in the following way:
a)
Take off the cover plate
(8A)
on the back of the mixer.
b)
Take out the frequency converter
(8)
with fittings
(8D).
c)
The bowl lift micro
(12)
with fittings
(12A)
can be taken out by
loosening the two screws
(12B)
and removing the two wires. The
micro can not be exchanged.
d)
Mount the new micro switch by following the instructions in reverse
order. No adjustment is required.