background image

7

FIGURE 7

FIGURE 8

FIGURE 9

FIGURE 10

Mounting the Heat Exchanger
to All Models

NOTE:

 The units are very top heavy when attached only at the

return union. Make sure that the unit is well supported during fit
up. Mounting of the RXLD Models requires more than one
person.

Using thread seating compound install the included PEX lined
steel nipples into the side loop connections. Thread the return

fitting onto the lower PEX nipple and tighten the union nut firmly
by hand, see Figure 7. Set the heat exchanger on the return
fitting, see Figure 8. Then connect the supply fitting and rotate it
so that the pipe contacts the pump., see Figure 9. It may be
necessary to make a preliminary cut on the pipe to allow this.
Mark the pipe at the top of the pump and add 5/8” for solder
socket engagement, see Figure 9. Remove and cut the pipe at
the second mark. Reinstall the supply side assembly inserting
first into the pump and then connect it at the union, see
Figure 10. Make any adjustments needed to the length of the
support leg on units so equipped.

Summary of Contents for RXLD-52

Page 1: ..._____________ STREET ADDRESS__________________________________ CITY STATE ZIP_____________________________________ PHONE __________________________________________ DISTRIBUTOR_________________________...

Page 2: ...to 40 degrees dependent on application A field supplied pump on the secondary side will circulate water into the bottom fitting of the heat exchanger out the top and through a heating distribution sys...

Page 3: ...Q 29 600 ALL XL MODELS DYNA GCVT 40Q 35 500 ALL XL MODELS CLEAN II GCVT 50Q 38 000 ALL XL MODELS GCVX 50Q 50 100 ALL XL MODELS GCG 65Q 49 400 ALL XL MODELS FCG 75Q 60 100 ALL XL MODELS GDVH 40L 30 000...

Page 4: ...xchanger temperature differentials Delta T are shown for reference only Actual values can be calculated by Delta T Btuh 500 gpm This will determine the difference between the heat exchanger s inlet an...

Page 5: ...on Closed loop secondary side piping should always include a pressure relief valve expansion tank drain valve and air separation device Installers should also provide isolation valves purge valves sta...

Page 6: ...ectly the relay can be bypassed and removed All wiring in the pump s termination box should be rated for 60 C or greater and is to be done in accordance with national and local electric codes MOUNTING...

Page 7: ...EX nipple and tighten the union nut firmly by hand see Figure 7 Set the heat exchanger on the return fitting see Figure 8 Then connect the supply fitting and rotate it so that the pipe contacts the pu...

Page 8: ...Front Cover Single Wall Models RXLS 28 RXLS 52 184906 000 Double Wall Model RXLD28 184910 000 Double Wall Model RXLD52 184910 001 8 Heat Exchanger Single Wall Model RXLS 28 184903 000 Single Wall Mod...

Reviews: