GENERAL INFORMATION

This manual contains instructions for the installation, operation
and maintenance of the Promax

®

 XL Heat Exchanger. Read it

carefully before installing or using and keep it for future reference.

Intended Applications

The XL Series of heat exchangers provide the means to obtain
an isolated source of hot water for radiant floor or wall heating,
hydronic air handling units and other closed loop applications.
The product line includes single wall and atmospherically  vented
double wall heat exchangers with two separate btuh inputs for
each. The XL Series is intended for connection with the
A.O. Smith Promax

®

 SL line of gas-fired water heaters. This unit

is not to be connected to pool or spa systems having highly
chlorinated water.

Rating Plate

A rating plate identifying the heat exchanger will be found on
the front of the unit. When referring to the heat exchanger, always
have the information listed on the rating plate readily available.

Customer Responsibilities

Please take the time to read not only this manual but also the
warranty sheet enclosed. Warranty of the Promax XL heat
exchanger and its parts will depend on proper installation,
maintenance and operation. Furthermore, the warranty shall be
void if the design or structure of the heat exchanger is, or is

TABLE OF CONTENTS

The pump on the XL unit draws water off of the top side loop
connection fitting (Supply Fitting), circulates it through the primary
side of the heat exchanger and back to the tank through the
return connection. While passing through the heat exchanger,
the water will lose from 10 to 40 degrees dependent on
application. A field supplied pump on the secondary side will
circulate water into the bottom fitting of the heat exchanger, out
the top and through a heating distribution system such as a
radiant slab or air handler. The rise in temperature for secondary
side fluid is very much dependant on application but should be
designed to provide 10 to 30° rise.

THEORY OF OPERATION

attempted to be, modified or altered in any way, including, but
not limited to, by attaching non-Company approved appliances
or equipment. The manufacturer of this heat exchanger will not
be liable for any damages because of failure to comply with the
installation and operating instructions outlined on the following
pages. Use them as a guide to check the propriety of the heat
exchanger installation. You will need to maintain the heat
exchanger and water heater as outlined in their respective
manuals. Equipment in this carton was inspected and verified
to be in good condition at the time it left the factory. When
received, a visual inspection of the equipment should be made
and any damage noted on the delivery receipt. A damage claim
should be filed immediately with the carrier.

ALL TECHNICAL AND WARRANTY QUESTIONS SHOULD BE
DIRECTED TO THE LOCAL DEALER FROM WHOM THE HEAT
EXCHANGER WAS PURCHASED. IF YOU ARE UN-
SUCCESSFUL, PLEASE WRITE TO:

Repair Parts

For service or repair parts contact:

First: The Installing Contractor

Second: The local Distributor

AOSmith Water Products Company, Inc.
500 Lindahl Parkway
Ashland City, TN 37015
www.aosmithwaterheaters.com

FIGURE 1

GENERAL INFORMATION .................................................. 2
TABLE OF CONTENTS ....................................................... 2
THEORY OF OPERATION .................................................. 2
SELECTING EQUIPMENT .................................................. 3
HEAT EXCHANGER PERFORMANCE ............................... 4

TYPICAL INSTALLATION ................................................. 5,6
WIRING ................................................................................ 6
MOUNTING THE HEAT EXCHANGER
TO WATER HEATER ........................................................ 6,7
REPLACEMENT PARTS ...................................................... 8

Summary of Contents for RXLD-52

Page 1: ..._____________ STREET ADDRESS__________________________________ CITY STATE ZIP_____________________________________ PHONE __________________________________________ DISTRIBUTOR_________________________...

Page 2: ...to 40 degrees dependent on application A field supplied pump on the secondary side will circulate water into the bottom fitting of the heat exchanger out the top and through a heating distribution sys...

Page 3: ...Q 29 600 ALL XL MODELS DYNA GCVT 40Q 35 500 ALL XL MODELS CLEAN II GCVT 50Q 38 000 ALL XL MODELS GCVX 50Q 50 100 ALL XL MODELS GCG 65Q 49 400 ALL XL MODELS FCG 75Q 60 100 ALL XL MODELS GDVH 40L 30 000...

Page 4: ...xchanger temperature differentials Delta T are shown for reference only Actual values can be calculated by Delta T Btuh 500 gpm This will determine the difference between the heat exchanger s inlet an...

Page 5: ...on Closed loop secondary side piping should always include a pressure relief valve expansion tank drain valve and air separation device Installers should also provide isolation valves purge valves sta...

Page 6: ...ectly the relay can be bypassed and removed All wiring in the pump s termination box should be rated for 60 C or greater and is to be done in accordance with national and local electric codes MOUNTING...

Page 7: ...EX nipple and tighten the union nut firmly by hand see Figure 7 Set the heat exchanger on the return fitting see Figure 8 Then connect the supply fitting and rotate it so that the pipe contacts the pu...

Page 8: ...Front Cover Single Wall Models RXLS 28 RXLS 52 184906 000 Double Wall Model RXLD28 184910 000 Double Wall Model RXLD52 184910 001 8 Heat Exchanger Single Wall Model RXLS 28 184903 000 Single Wall Mod...

Reviews: