CIRCULATING LOOP HEAT EXCHANGER

PRINTED IN THE U.S.A. 0804

PART NO. 184911-000

Fill in the Rating Pate Information Here:

MODEL NO.________________________________________

SERIAL NO.________________________________________

INSTALLATION DATE________________________________

Month

      Day        Year

Fill in the Installation Information Here:

INSTALLER________________________________________

STREET ADDRESS__________________________________

CITY/STATE/ZIP_____________________________________

PHONE #__________________________________________

DISTRIBUTOR________________________________________

STREET ADDRESS__________________________________

CITY/STATE/ZIP_____________________________________

PHONE #__________________________________________

SAVE THIS MANUAL FOR FUTURE REFERENCE.

  CAUTION

PLEASE READ THOROUGHLY BEFORE INSTALLING AND
USING THIS APPLIANCE.

MANUAL

www.aosmithwaterheaters.com

• Installation

• Operation

• Maintenance

PROMAX

®

 XL

MODELS

Summary of Contents for RXLD-52

Page 1: ..._____________ STREET ADDRESS__________________________________ CITY STATE ZIP_____________________________________ PHONE __________________________________________ DISTRIBUTOR_________________________...

Page 2: ...to 40 degrees dependent on application A field supplied pump on the secondary side will circulate water into the bottom fitting of the heat exchanger out the top and through a heating distribution sys...

Page 3: ...Q 29 600 ALL XL MODELS DYNA GCVT 40Q 35 500 ALL XL MODELS CLEAN II GCVT 50Q 38 000 ALL XL MODELS GCVX 50Q 50 100 ALL XL MODELS GCG 65Q 49 400 ALL XL MODELS FCG 75Q 60 100 ALL XL MODELS GDVH 40L 30 000...

Page 4: ...xchanger temperature differentials Delta T are shown for reference only Actual values can be calculated by Delta T Btuh 500 gpm This will determine the difference between the heat exchanger s inlet an...

Page 5: ...on Closed loop secondary side piping should always include a pressure relief valve expansion tank drain valve and air separation device Installers should also provide isolation valves purge valves sta...

Page 6: ...ectly the relay can be bypassed and removed All wiring in the pump s termination box should be rated for 60 C or greater and is to be done in accordance with national and local electric codes MOUNTING...

Page 7: ...EX nipple and tighten the union nut firmly by hand see Figure 7 Set the heat exchanger on the return fitting see Figure 8 Then connect the supply fitting and rotate it so that the pipe contacts the pu...

Page 8: ...Front Cover Single Wall Models RXLS 28 RXLS 52 184906 000 Double Wall Model RXLD28 184910 000 Double Wall Model RXLD52 184910 001 8 Heat Exchanger Single Wall Model RXLS 28 184903 000 Single Wall Mod...