14
INSTALLATION AND REPLACEMENT OF MEMBRANE FLUSH PROCEDURES
1. Disconnect the plug from the socket.
2. Turn off the water supply valve.
3. Turn the Jaco fittings clockwise.
4. Unscrew membrane housing’s cap by turning it
clockwise.
5. Grasp the membrane with a clamp and pull out.
6. Push new membrane carefully into the housing until
it stops.
After installing the membrane, screw the cap and
reinsert the tube in the same way. Open RO tap to
clean the newly installed membrane filter. Let the
system run for 2 hours and the water run out. Then,
you can drink the purified water.
1. Open the tube union of 3rd housing and discharge
the water supplied to Sedimentfilter, Activated
Carbon filter and BlockCarbon filter. Perform
washing for 10 minutes.
2. First three filters are washed. If post-carbonand
mains pressure are present, mineral filter is washed
with the mains pressure for 10 minutes. Waste
water is discharged from the faucet.
3. The membrane filter is pushed in the housing with
the O-ring side first and the housing capis screwed.
Water is supplied to the membrane. The water
first-supplied to the membrane should be flown out
without reaching the tank and the post carbon. The
water should be drained for 10 min.
Membrane replacement and housing sanitisation
as seen in figures;
• Open drinking water faucet.
• Loose the union of the membrane housing on the
water inlet side and disconnect tubing from the
housing.
• Unscrew the membrane housing from the cap (with
pliers) and displace the used membrane.-Clean
the membrane housing with disinfectant (bleach
solution) and rinse the housing. Wet or wipe the
O-ring at the bottom of thenew membrane element
for being seated properly. Push the membrane
into the housing with o-ring side first. Ensure the
membrane fit into the housing properly.
• Screw the cap back onto the membrane housing
and tighten with hand or the supplied wrench.
• Finally, place the union at the water inlet side of the
membrane properly and tighten firmly.
!! ATTENTION !!
The water first-supplied to the device should
be discharged after passing through the filters.
It should definitely not contact the tank and
post carbon
Do not forget to connect the power plug to the
socket in models with pump.
The treatment device must not be supplied with
hot water. Otherwise, all filters will be damaged
and the device will be out of warranty.