4
Use
4.1
Set a parameter value
To set a parameter value:
Press [MENU] to access the user menu.
Press [ ] or [ ] to scroll to the concerning parameter, refer to Parameters (see
section 3.1.3).
Press [ENTER] to select.
Use [ ] or [ ] to change the parameter value.
Press [ENTER] to confirm.
Press [RESET] to go back to the main menu.
Press [RESET] to leave the user menu.
4.2
Turn on the water heater
To start the water heater:
Make sure the water heater connects to the mains power supply.
Set the control switch on the side of the water (see section 1) heater to I.
The display will show
ini
for about 10 seconds.
When the display shows
OFF
the water heater is ready to use.
4.2.1
Switch to ON mode
To switch to ON mode (see section 3.2.1.2), change parameter
001
to
ON
parameter value (see section 4.1).
4.2.2
Set the water temperature
To change the temperature setpoint:
Adjust parameter
002
, refer to Set a parameter value (see section 4.1), or
Directly from ON mode:
Directly use [ ] or [ ] to set the temperature value.
Press [ENTER] to confirm.
4.3
Turn off the water heater
4.3.1
Turn off for a short period
To turn off the water heater for less than 2 months, change parameter
001
to
OFF
, refer to
Set a parameter value (see section 4.1).
The water heater will switch to OFF mode (see section 3.2.1.1) and the frost protection is
on.
Caution
The anode protection remains active when the OFF mode is selected.
Note
If the water heater is in OFF mode for more than 2 months and no water is drained, air
bubbles may be formed in the water heater. This can lead to air in the water pipes.
1.
2.
3.
4.
a.
b.
5.
1.
2.
3.
•
•
a.
b.
c
n
0312266_INNOVO_UKUK_V3.0, 2017-02-10
25
Summary of Contents for Innovo 12-160
Page 6: ...6...
Page 13: ...User part 0312266_INNOVO_UKUK_V3 0 2017 02 10 13...
Page 14: ...14...
Page 16: ...16 User part...
Page 18: ...18 User part...
Page 24: ...24 User part...
Page 27: ...Installation Maintenance and Service part 0312266_INNOVO_UKUK_V3 0 2017 02 10 27...
Page 28: ...28 User part...
Page 36: ...36 Installation Maintenance and Service part...
Page 43: ...Fig Venting systems 0312266_INNOVO_UKUK_V3 0 2017 02 10 43...
Page 58: ...58 Installation Maintenance and Service part...
Page 70: ...70 Installation Maintenance and Service part...
Page 83: ...0312266_INNOVO_UKUK_V3 0 2017 02 10 83...
Page 87: ...13 5 Declaration of conformity 0312266_INNOVO_UKUK_V3 0 2017 02 10 87...