Key Features 

 

Glass Coated Element 

Scale and sediment build up on the surface of standard elements lead to premature 
failure. An A. O. Smith glass coated element helps to prevent scale formation on the 
element, extending the life of the element.   

 

 

Blue Diamond Glass Lining   

A. O. Smith water heaters come with special glass lined inner containers. This lining is 

achieved through a specialized fusion process carried out at 870ºC. Inner tanks are 

designed to pass the 100,000 cycle fatigue life test in accordance with relevant UL 

(Underwriters’ Laboratories) Standards. This makes our tanks one of the best inner 

containers, resistant to rust and scaling. 

 

Anode Rod Protection   

The tank has an anode rod system with a stainless core that is designed to protect the 
tank from corrosive elements. The system uses a special cathodic action to fight the 
corrosive elements, prolonging the life of the water heater.   

 

 

Safety Valve 

This water heater has a pressure safety valve. This valve is designed to automatically 
relieve and discharge water in case the pressure or temperature exceeds the preset 
limits.   

 

 

Thermal Cut Out 

The water heater employs a thermal cut out. In case any fault occurs and the water 

temperature exceeds the highest preset temperature (93°C), the switch rapidly cuts off the 
live and neutral line for user’s safety. 

 

 

 

Summary of Contents for ELJH-30

Page 1: ...Storage Water Heater ELJH 30 ELJH 40 ELJH 50 ELJH 80 ELJH 100...

Page 2: ...of homeowners contractors architects and specifying engineers in over 60 countries by providing innovative energy efficient products designed for years of trouble free service Today A O Smith Water P...

Page 3: ...fety Valve Thermal Cut Out Installation 6 Mounting Mounting procedures and precautions Mounting guidelines Plumbing connection Water inlet and outlet connection Power connection Wiring diagram of wate...

Page 4: ...75 5 35 75 5 Rated water pressure MPa 0 8 0 8 0 8 0 8 0 8 Minimum inlet water pressure MPa 2 0 2 0 2 0 2 0 2 0 Maximum inlet water pressure MPa 3 0 3 0 3 0 3 0 3 0 Inlet outlet connection inches Water...

Page 5: ...mperature indicator 7 Multi function safety valve 2 Heating element 8 Stopcock not included with water heater 3 Anode 9 Pilot light 4 Cold water inlet pipe with diffuser 10 Inlet 5 Hot water outlet pi...

Page 6: ...rds This makes our tanks one of the best inner containers resistant to rust and scaling Anode Rod Protection The tank has an anode rod system with a stainless core that is designed to protect the tank...

Page 7: ...water heater is not installed on the weight bearing wall or is mounted on hollow brick wall corresponding protective measures must be provided This water heater must be installed with the fixing acce...

Page 8: ...s are permitted Ensure the screw is not excessively tightened This may damage the expansion tubes Insert the square holes of the upper of supporting rack at the back of the water heater onto the brack...

Page 9: ...ted regularly to remove lime deposits and to verify that it is not blocked The hot water pipe is connected to the water outlet outlet pipe has a red cap If the water pressure of the inlet pipe approac...

Page 10: ...manufacturer its service agent or similarly qualified persons in order to avoid a hazard Wiring diagram 1 Thermostat setting knob 4 Power supply connection 2 Pilot light 5 Ground connection 3 Thermal...

Page 11: ...itions the safety valve lever should be opened periodically If water flows from the valve it is in good working condition Otherwise please contact a local authorized A O Smith dealer Maintenance instr...

Page 12: ...this end The water inlet pipe connection is connected to floor drain by pipes Discharge water from this end 4 Open the water inlet valve to get the maximum tap water flow and flush the tank till the...

Page 13: ...d facing 1 Disconnect power to heater immediately 2 Check and direct condensation pipe downwards 3 Contact local authorized dealer CAUTION Before installing the heater ensure that the power source and...

Reviews: