7
Mounting guidelines
Drill two holes at least 90 mm in depth using an electric impact drill with
a Ø 10
mm bit. The holes must be
level. Space between the two holes should be as shown in the table.
A
plastic expansion tube must be placed into the drilled
holes before the brackets are inserted.
It is necessary to use a special inner hexagon spanner to fasten the bolts into the expansion tubes, no other
tools are permitted. Ensure the screw is not excessively tightened. This may damage the expansion tubes.
Insert the square holes of the upper of supporting rack at the back of the water heater onto the brackets,
then press the water heater down firmly to ensure the holes are lodged against the brackets.
Model
L (mm)
ELJH-30
260
ELJH-40
260
ELJH-50
380
ELJH-60
380
ELJH-80
380
ELJH-100
380
CAUTION:
•
The mounting accessories provided can only be used for solid walls, as shown in the drawing above.
Improper installation may cause the water heater to dislodge.
100mm depth
correct installation
incorrect installation