Conversion to a different gas category
40
Instruction manual BFC
4
is
1. Isolate the water heater from the power supply
(10.3 "Electrically isolating
the appliance")
.
2. Shut off the gas supply.
3. Undo the screws of the plastic covers.
4. Carefully remove the covers from the top of the appliance.
5. Detach the connector (1) that connects the leads of the hot surface igniter
and the flame probe to the controller.
6. Detach the three-part gas coupling (2) adjacent to the burner.
-
Detach the air supply hose (3).
-
Detach the pressure switch hose (4).
7. Remove the burner as complete assembly.
8. Place and fit the burner with parts from the conversion kit.
Note
The burner for LP gases can be recognised by the letter 'P' which is stamped
into the metal of the gas/air distribution plate (5).
9. Select and fit the correct orifice from the conversion kit, based on the gas
table
(3.4.3 "Gas data")
. The injector diameter is stamped into each injector
(6).
Conversion of gas control
Legend
7. burner pressure regulator
8. blank plate
9. gas control connector
7
8
9
IMD-0079b R2
Summary of Contents for Cyclone BFC - 30
Page 2: ...www aosmithinternational com your installer...
Page 4: ...4 Instruction manual BFC gis...
Page 8: ...Table of contents 8 Instruction manual BFC...
Page 27: ...Instruction manual BFC 27 is Types of appliances IMD 0468 R0 C43 C13 C53 B23 C33...
Page 42: ...Conversion to a different gas category 42 Instruction manual BFC 4 is...
Page 48: ...Draining 48 Instruction manual BFC 6 gis...
Page 54: ...Status of the appliance 54 Instruction manual BFC 8 gis...
Page 58: ...Shutting down 58 Instruction manual BFC 10 gis...
Page 82: ...is Instruction manual BFC 82...
Page 84: ...Maintenance frequency 84 Instruction manual BFC 14 is...
Page 94: ...Appendices 94 Instruction manual BFC 17 is...
Page 96: ...Instruction manual BFC 96...