NEED HELP? GIVE US A CALL
877.333.7108
INSTALLATION GUIDE 4
1. Connect 3/8" tubing to the bottom
port of the dual adapter. Run the
opposite end of the tubing to the left
side of the system head and cut to
length.
2. Using the second piece of 3/8" tubing,
connect one end to the top of the dual
port adapter and run it to the right side
of the system head and cut to length.
3. Connect tubing at all points. Push the
tubing in until it stops. Use 3/8" quick
connect elbow if necessary.
INLET
OUTLET
Turn on COLD water to the kitchen faucet
(1). With the faucet on, slowly open the
COLD water shutoff valve (2).
Leave water running to flush system for 15
minutes or until water is clear of carbon fines.
While the system is flushing, check for leaks.
Once system is flushed, turn off kitchen faucet.
Note: Do not drink flushed water.
STEP 6
Connect Tubing
STEP 7
Turn on Cold Water
STEP 8
Flush System
1
2