Furnace Installation and Owners Manual
18
LDJ620_E01_R03_2006.03
Models LDJ620-9 and LDJ620-10
M
A I N T E N A N C E
Daily Maintenance
• Inspect Burner
During use, ash and clinkers will be pushed
out over the top of the burner pot (1) as fuel is
augered in at the bottom. Clinkers that
appear to be stuck to the side of the burner
must be loosened with the included clinker
tool.
• Check Fuel Supply
Check level of corn/pellets in storage bin (2).
Refill as necessary to maintain an adequate
supply.
Weekly Maintenance
• Check Ash Drawer
Check ash drawer (3) and empty as needed.
Ashes should be placed in a metal container
with a tight fitting lid. The closed container of
ashes should be placed on a non-
combustible floor or on the ground, well away
from all combustible materials pending final
disposal. If the ashes are disposed of by
burying in soil or otherwise dispensed, they
should be retained in the closed container
until all clinkers have thoroughly cooled.
1
2
3