SURFACE STEAMER SS-400TT
8
P/N 1011073 Rev. H 12/13
McDonald’s
A.J. Antunes & Co.
PROGRAMMING
Programming the Surface Steamer
1. Press and hold the
PROGRAM
button until “
CYC
”
appears on the display (Figure 5) then release the
PROGRAM
button.
2. Press the
OK
button. The unit displays the cur-
rently programmed cycle time.
3. Press the
UP
or
DOWN
arrow buttons to increase
or decrease the cycle time in one second incre-
ments (from 1 to 60). Release all buttons at the
desired setting. Then press the
PROGRAM
button
to save changes.
NOTE: To save Programming changes, be sure to
press the PROGRAM button (Figure 5) as soon as
changes are made.
Table 1. Programmable Features & Parameters
Default Values
Value
Description
Defaults
CYC
Length of the steam cycle in seconds. Available ranges are from 1 to 60 seconds
adjustable in 1 second increments.
12 seconds
SHOT
Regulates the amount of water volume injected at each solenoid valve opening. A higher
value equals more water; a lower value equals less water. Available ranges are .05 to
1.00 seconds adjustable in .05 second increments.
0.20
Intr
Interval - Time between injections of water. Available ranges are 0 to 10 seconds in
increments of 1 second.
4
SETP
Setpoint temperature of the unit. Available ranges are 350°F (176ºC) to 400ºF (204ºC).
Increments: 1
400
RPT
Repeat - Number of times the audio signal repeats at the conclusion of a steam cycle
(1 to 255). Increments: 1
2
DEGF/
DEGC
Allows the user to select whether the unit displays temperatures in degrees Fahrenheit
or Celsius.
DEGF
OK
1
2
3
4
READY
STEAM
POWER
Channels 1
through 4
Unit
Display
Steam
Activation
Button
Power
Button
Program
Button
Up
Arrow
Button
Down
Arrow
Button
OK
Button
Figure 5. Primary Control Panel View
NOTE: During programming mode, the display
returns to operation mode after 5 seconds of
inactivity.
4. To program values listed in Table 1, repeat Step 1
but press
UP
until the desired value is displayed.
Then press
OK
and use the
UP
or
DOWN
arrows
to adjust. Press the
PROGRAM
button to save
changes, press the
UP
or
DOWN
arrow
buttons to
move to the next value (Table 1).
Table 1 describes programmable features and param-
eters of the Surface Steamer: All four steam channels
are programmed to these default values at the factory.
Factory Resets
Follow these steps to restore the system to the factory
preset setting:
1. Turn the power switch
OFF
.
2. Press and hold the
UP
and
DOWN
arrow buttons
simultaneously and turn the power switch
ON
.
3. Do not release the buttons until after 3 seconds.
Generator Temperature
To view the actual temperature for the front generators,
press and hold the
UP
arrow button.
To view the actual temperature for the rear generators,
press and hold the
DOWN
arrow button.