9
Vertical contact toaster
P/N 1011097 Rev. A 03/12
A.J. Antunes & Co.
temperatUre cOntrOl panel
nOte: the term “setpoint temperature” refers to
the desired temperature setting.
To display the actual Platen temperature—providing it
is over 440°F (227°C)—press the
temp Up
button.
To display the actual Auxiliary Air Heater temperature—
providing it is over 360°F (182°C)—press the
temp
DOwn
button.
To switch the temperature display between Fahrenheit
(°F) and Celsius (°C), press and hold the
temp
scale
button for 5 seconds.
platen heater temperatUre aDJUstment
1. Turn the power on and wait for the Temperature
Display to finish the power up sequence
(Figure 4).
2. Press and hold both
temp Up
and
temp DOwn
buttons for over 1 second until the display flashes
the Platen setpoint temperature (Figure 5), then
release.
3. Press the
temp Up
button to raise the setpoint
temperature or press the
temp DOwn
button to
lower the setpoint temperature.
nOte: the maximum platen setpoint temperature
is 600
°
f (316
°
c). If no change in temperature is
made within 5 seconds, the display reverts back to
the previous setpoint temperature.
4. Release the button when the desired setpoint
temperature is displayed.
aUxIlIary aIr heater temperatUre aDJUstment
1. Turn the power on. Wait for Temperature Display
to finish the power up sequence (Figure 4).
2. Press and hold both
temp Up
and
temp
scale
buttons for over 1 second until the dis-
play flashes the setpoint temperature (Figure 6),
then release.
3. Press the
temp Up
button to raise the setpoint
temperature or press the
temp DOwn
button to
lower the setpoint temperature.
nOte: the maximum auxiliary air heater setpoint
temperature is 400°f (204
°
c).
4. Release the button when the desired setpoint
temperature is displayed.
nOte: If no change in temperature is made within
5 seconds, the display reverts back to the previous
setpoint temperature.
TEMP
UP
TEMP
DOWN
TEMP
SCALE
˚F
˚C
POWER
TEMP
UP
TEMP
DOWN
TEMP
SCALE
˚F
˚C
POWER
SP - P
600
TEMP
UP
TEMP
DOWN
TEMP
SCALE
˚F
˚C
POWER
TEMP
UP
TEMP
DOWN
TEMP
SCALE
˚F
˚C
POWER
400
SP - A
figure 4. temperature power Up sequence
3. SP-A (Setpoint Auxiliary)
is displayed
1. SP-P (Setpoint Platen)
is displayed
“Heat On” LED will blink on/off during warm-up and when either
platen or auxiliary air heaters are calling for heat.
2. Current Platen setpoint
temperature setting is displayed
4. Current Auxiliary Air setpoint
temperature is displayed
5. LO is displayed until
Platen temperature rises
above 550°F (288°C)
6. USE is displayed when
Platen setpoint temperature*
is reached
TEMP
UP
TEMP
DOWN
TEMP
SCALE
°F
°C
POWER
LO
TEMP
UP
TEMP
DOWN
TEMP
SCALE
F
C
POWER
USE
* platen setpoint temperature must be between
460°f (238°c) and 600°f (316°).
OperatIOn (continued)