Page 23
PROBLEM
Engine is running,
but no AC output is
available.
1. AC Circuit breaker is open.
2. Fault in generator.
3. Poor connection or defective cord set.
4. Connected device is bad.
5. GFCI outlet is open (if equipped)
1. Check AC load and reset circuit breaker.
2. Contact customer service or authorized service center.
3. Check and repair.
4. Connect another device that is in good condition.
5. Correct ground fault and press reset button on GFCI outlet.
Engine runs well at
no-load, but "bogs
down" when loads is
connected.
1. Short circuit in a connected load.
2. Engine speed is too slow.
3. Generator is overloaded.
4. Shorted generator circuit.
5. Clogged or dirty fuel filter.
6. Connected device is bad.
1. Disconnect shorted electrical load.
2. Contact customer service or authorized service center.
3. Reduce load.
4. Contact customer service or authorized service center.
5. Clean or replace fuel filter.
6. Connect another device that is in good condition.
Engine will not start;
starts and runs rough
or shuts down when
running.
1. Engine switch set to OFF (O) position.
2. Fuel valve is in OFF (O) position.
3. Low oil level.
4. Dirty air filter.
5. Out of fuel.
6. Stale fuel.
7. Spark plug wire not connected to spark plug.
8. Bad spark plug.
9. Water in fuel.
10. Flooded.
11. Excessively rich fuel mixture.
12. Intake valve stuck open or closed.
13. Engine has lost compression.
14. Clogged or dirty fuel filter.
15. Shut off due to CO accumulation &
blinking red indicator light
16. Shut off due to a system fault & blinking
yellow indicator light
17. Clogged or dirty spark arrester screen.
1. Set engine switch to ON (l) position.
2. Move fuel valve to ON (l) position.
3. Fill crankcase to proper level or place generator on
level surface.
4. Clean or replace air cleaner.
5. Fill fuel tank.
6. Drain fuel tank and carburetor; fill with fresh fuel.
7. Connect wire to spark plug.
8. Replace spark plug.
9. Drain gas tank and carburetor; fill with fresh fuel.
10. Wait 5 minutes and re-crank engine.
11. Contact customer service or authorized service center.
12. Contact customer service or authorized service center.
13. Contact customer service or authorized service center.
14. Replace fuel filter.
15. Follow all safety instructions on CO Action Label.
16. Contact customer service or authorized service center.
17. Clean or replace spark arrester screen.
Engine lacks power.
1. Load is too high.
2. Dirty air filter.
3. Clogged or dirty fuel filter.
4. Clogged or dirty spark arrester screen.
5. Engine needs to be serviced.
6. Bad fuel.
1. Reduce load.
2. Replace air filter.
3. Clean or replace fuel filter.
4. Clean or replace spark arrester screen.
5. Contact customer service or authorized service center .
6. Drain gas tank and carburetor; fill with fresh fuel.
Engine“hunts”or falters. 1. Carburetor is running too rich or too lean.
2. Clogged or dirty fuel filter.
3. Choke is opened too soon.
1. Contact customer service or authorized service center .
2. Replace fuel filter.
3. Set choke to halfway position until engine runs smootly.
Engine shuts down
when running.
1. Out of fuel.
2. Dirty air cleaner.
3. Low oil level.
4. Shut off due to CO accumulation &
blinking red indicator light
5. Shut off due to a system fault & blinking
yellow indicator light
1. Fill fuel tank.
2. Clean or replace air cleaner.
3. Fill crankcase to proper level or place generator on
level surface.
4. Follow all safety instructions on CO Action Label.
5. Contact customer service or authorized service center .
POSSIBLE CAUSE
SOLUTION
TROUBLE SHOOTING
Summary of Contents for SUA5000P
Page 26: ...Page 24 PARTS DIAGRAM PARTS DIAGRAM AND PARTS LIST SUA5000P 357B 6 6B 357B 6 6B ...
Page 32: ......
Page 33: ......
Page 34: ...Fontana CA 92337 USA Phone 1 855 888 3598 support a ipower com www a ipower com ...
Page 36: ...Fontana CA 92337 USA Phone 1 855 888 3598 support a ipower com www a ipower com ...
Page 70: ......
Page 71: ...Fontana CA 92337 USA Téléphone 1 855 888 3598 support a ipower com www a ipower com ...
Page 73: ...Fontana CA 92337 USA Téléphone 1 855 888 3598 support a ipower com www a ipower com ...
Page 109: ......
Page 110: ...Fontana CA 92337 EE UU Teléfono 1 855 888 3598 support a ipower com www a ipower com ...
Page 112: ...Fontana CA 92337 EE UU Teléfono 1 855 888 3598 support a ipower com www a ipower com ...