PAIRING / CUTTING OUT OF THE ELECTRONIC KEYS CHD 400:
EMERGENCY DESACTIVATION
USE OF THE MAIN CODE
ALARM FUNCTIONS
DOORS, BONNET, BOOT OPENING AND ADDITIONAL MODULES:
With the system in off position enter the MAIN CODE as shown on the PIN CARD.
When the confirmation BEEPS end and the LED is switched on fixed again, within 15 seconds
press on the key socket for 3 close times the metallic part of each
If the contact is not close enough, although the confirmation signal, it could be necessary to
press the key again: only 3 close BEEPS and 3 LED flashings indicate the correct read in.
Once activated the last one (maximum 2 simultaneously), turn on/off the ignition key one time or
wait for 30 seconds.
-
The unused keys during this operation
-
The procedure can be cut off only in the initial phase, only if the first key has been pressed for
maximum 2 times.
-
After 20 seconds without doing anything the procedure is quitted.
-
The denial on the programming of further keys is signalised by 2 close BEEPS.
-
Once activated the procedure, it is possible to learn the remote controls.
The system can be desactivated without the remote control using the following procedure
shown on the
too, or using the emergency electronic key
(optional).
Remove the PIN CARD label: the main code is now shown.
Insert the ignition key and turn it one time on/off to switch the LED on (red pilot light).
Before the LED is switched off, press its button as many times as the first number of the code;
each time the LED switches off to confirm.
Wait until the LED is off and on again.
Repeat the 3-4 steps for each remaining code numbers.
When the system is activated the alarm is given/signalised by the siren, the direction indicators,
the LED and the additional warning horns.
Cycles of about 25 seconds, with cut off by the remote control or the emergency procedure.
The input can be set in two ways:
-
Instantaneous on the system activation
-
Delayed by 30 or 50 seconds on activation, then instantaneous.
The alarm cycle is not repeated if the door remains opened.
The alarm is repeated only if the door is closed and opened again after the current cycle is
terminated.
Unlimited alarm cycles.
key CHD 400 to be activated
or to keep working, waiting each time the LED relighting and the BEEP from the buzzer.
are desactivated; they can be activated again by
repeating the procedure.
PIN CARD
CHD 400
1
2
3
4
5
The usual desactivation signal confirms the operation has been completed successfully.
.
WARNING:
PRESS THE BUTTON ONLY WHEN THE LED IS ON
!
!
!
13
Summary of Contents for MED 2200
Page 2: ......