9dot GigaSync Manual Download Page 22

22 

 

 

 

 

 

GIGASYNC MANUAL 

VER. 3 REV. 1 

 

While the GDT does not act even when the voltage is rising rapidly, as it takes time to ionize the gas it contains, the TVS 
quickly goes into protection with a faster response. This device has high reliability as it contains solid state elements. 
 
Short circuit protection 
The GigaSync has short circuit protection in every port on every cartridge, both on the PoE and the terminal ports. 
This protection works as follows: 
If there is a short circuit on the connected load, the GigaSync will turn off the port to protect itself so as not to damage the 
device. After a few seconds it reactivates the door, always with the protection active; if the short circuit is still present then 
the protection trips again and will continue without powering the load until the situation normalizes, retrying every few 
seconds and indefinitely. 
If in any of the attempts GigaSync finds the normalized situation, it will turn on the port and power the load as it normally 
does. 
 
Some devices require a large amount of current when turned on, activating short circuit protection. The GigaSync will 
automatically  retry  after  a  few  seconds.  On  the  second  try,  this  required  current  is  usually  less  so  the  initial  problem 
disappears and the GigaSync will feed it correctly. 
 
Galvanic isolation between LAN and PoE 
The GigaSync has a PoE transformer on each port, which provides 1500 volt isolation between primary and secondary on 
all four pairs of structured PoE cables. 
This type of magnetic insulation of the PoE transformer prevents the propagation of a short circuit generated on the data 
cable  side  and  also  protects  against  overvoltages,  avoiding  the  passage  of  emissions  conducted  up  to  the  insulation 
voltage. Adding to the GigaSync, another strong point in terms of protections and making it one of the most complete on 
the market. 
 

Gigabit injector GS-G-POE 

The main function of the PoE injector of this device is to allow the power of other equipment on the network. GigaSync 
PoE injector cartridges are passive injectors. 

 

IMPORTANT NOTES:  

 

Unlike active PoE, passive PoE does not use any protocol to determine the type of device to power. It simply applies 
a type of voltage to its port without identifying what type of PoE standard or power supply voltage connected to 
the load is compatible with. Using an unsuitable voltage and/or wrong pinout can cause irreparable damage to the 
powered device. 

 

This cartridge does not provide the sync pulse. Only use for radios that do not require synchronization over power. 

 
It is possible to power a wide range of devices that accept different voltages, as this cartridge essentially replicates the 
voltage from the power terminals to the PoE output ports without applying any conversion. 
This gives us great versatility when connecting several PoE devices in the same infrastructure since it is possible to power 
each cartridge with a different voltage than the rest. 
 
In addition to supporting different voltages, the PoE injector has the possibility of selecting the pinout of the PoE output 
ports, and inserting a simple key, called the GigaKey, thus allowing powering a wide range of devices on the market. 
 
To find out if your PoE device can be powered via GigaSync, simply check the pinout that GigaKey allows you to select and 
make sure it matches the input pinout of your equipment

6

 
 
 

 

See section “GigaKey”  

Summary of Contents for GigaSync

Page 1: ...1 GIGASYNC MANUAL VER 3 REV 1...

Page 2: ...10 Injector Gigabit cartridge GS G POE GS G POE CS 10 Terminal s cartridge GS G TER 11 Terminal s cartridge with synchronization GS G TER CS 12 Cartridge label 13 Technical specifications 14 Installat...

Page 3: ...ect with the GigaSync 28 Command line interface 28 Access 28 Menu 30 SNMP interface 31 Web interface 32 Connection 32 Access 32 Interface description 33 Options bar 34 Synoptic diagram 37 Modules 38 S...

Page 4: ...e been made in the preparation of this document to ensure its accuracy 9dot assumes no responsibility for errors or omissions in this document or the use of the information contained therein 9dot rese...

Page 5: ...ork alone in dangerous conditions Only qualified personnel may install use and repair this system and its components Always assume electrical connections or conductors are live Turn off all switches a...

Page 6: ...r microswitches Hot swap modularity can manage up to 12 ports PoE or bipolar terminals The dual processor guarantees an interrupted operation of the unit in all the situations Remote management save t...

Page 7: ...works synchronization GigaSync can insert into the PoE ports the sync pulse used by Cambium Networks devices to sync the transmission Manages any type of PoE Each port can be configured to handle a di...

Page 8: ...t people and equipment For the correct operation of the dischargers it is necessary to connect the ground terminal GND Can be seen in the redundant power supply connectors of the base unit and the res...

Page 9: ...to detect the SSID Wi Fi signal of the type GSvx_ serial The software ID is a unique identification of the device Indications by the standards FCC CE e RoHS The indications of power requirements and t...

Page 10: ...Each PoE port has signaling LED that provides information on the status of the port on any faults and in the case of the POE CS version on the type of synchronization chosen On both sides there are s...

Page 11: ...provides information on the status of the door and any faults Each connector can be removed from the terminals for easier manipulation Through the main connector located behind the module is connecte...

Page 12: ...ignaling LED that provides information on the status of the port on any faults and if Cambium Sync synchronization is active or not Each connector can be removed from the terminals for easier manipula...

Page 13: ...TER or GS G TER CS with a brief description The serial number of the cartridge The power requirements voltage and current Type and range of output voltage and current Operating temperature range Indi...

Page 14: ...ce of voltage at the input SYNCHRONIZATION SPECIFICATIONS GPS external connector Type N female Sync input compatibility GigaSync of 9dot uGPS cnPulse and CMM5 of Cambium Networks Sync connectors Sync...

Page 15: ...ec Gigabit transformer Transmission speed 10BaseT 100BaseT 1000BaseT Canopy Sync n a Cambium Sync n a CARTRIDGES TER Product code GS G TER GS G TER CS Type Terminal Terminal Ports 4 4 Connector type T...

Page 16: ...s cartridge each port can power a device that consumes up to 3A and this is true However special care must be taken because in this case the total current will be limited by the typical cartridge curr...

Page 17: ...ed to the base structure with the supplied fixing screws Likewise the main connector offers enough strength to prevent them from inadvertently pulling out To remove the cartridge firmly pull the remov...

Page 18: ...e GigaSync are considered the first 3 LEDs arranged vertically to the left of the front LED Color Description SYNC flashing green 200ms Presence of sync pulse in selected input GPS or SYNC IN STATUS f...

Page 19: ...se unit are accessible through two redundant connectors are isolated from each other and no conversion is made to the applied voltage In this way it is possible to simultaneously connect different typ...

Page 20: ...an be powered through the main input via redundant terminals The main input of the base unit has an isolated DCDC converter that powers the two CPUs In this way maximum immunity against over voltages...

Page 21: ...ion Double phase protection is a circuit protection technology for high voltage environments Both technologies combined offer us great advantages to protect each port from voltage spikes The GigaSync...

Page 22: ...ated on the data cable side and also protects against overvoltages avoiding the passage of emissions conducted up to the insulation voltage Adding to the GigaSync another strong point in terms of prot...

Page 23: ...y has been designed to avoid handling the microswitches or jumpers that normally perform this function but are subject to errors This simplifies selection and executable simply by inserting the chosen...

Page 24: ...t is possible to power each cartridge with a different voltage than the rest Power supply and synchronization GS G TER CS In addition to guaranteeing all the functions of the GS G TER cartridge it off...

Page 25: ...e the Cambium Networks sync modes as described in the following table GS G POE CS External antenna Sync Input Method of synchronization GPSA GigaSync uGPS cnPulse CMM5 Canopy Sync Cambium Sync Table 7...

Page 26: ...is used to replicate the sync pulse regardless of how it was acquired The pinout is as follows Pinout Sync Output RJ12 Pin Sync Voltage range 1 TX 5V DC 2 n c 3 n c 4 n c 5 GND 6 GND Table 11 GigaSync...

Page 27: ...he Sync Output port of the other and vice versa This way in case of problems with one of the antennas coaxial cable internal GPS etc It will be possible remotely to re establish synchronization from t...

Page 28: ...ugh the web interface It is also possible to query and configure the system using the SNMP and API protocols Command line interface The SSH interface allows you to control some accessible parameters o...

Page 29: ...ing that the IP address has been permanently added to the list of known hosts After that it will ask us for the password and we must enter the default one password As soon as you log in the 9dot logo...

Page 30: ...ackages Displays the list of valid packages loaded upgrade The software update procedure begins Users o add Add a new user o edit Edit an existing user o list Show user list o remove Remove a user Wif...

Page 31: ...the operation of the interface you can execute a walk snmp command from the SSH shell using the IP of the GigaSync snmpwalk v 3 l authNoPriv u admin a sha A password m genmib mib IP GigaSync 1 3 6 1...

Page 32: ...Fi are enabled by default and can be disabled from the interface The web interface works with the following browser version and later Chrome Version 91 0 4472 114 Official build x86_64 Firefox 87 0 64...

Page 33: ...e to monitor in real time the applied voltage and the load parameters and to send commands of on off power cycle and synchronization Interpretation of the data is further facilitated by the ability to...

Page 34: ...ttons on the bar below Stop The Stop button deactivates all GigaSync outputs After pressing it it will ask if we are sure ATTENTION This deactivates all outputs of the GigaSync but does not disconnect...

Page 35: ...diagnosis IMPORTANT NOTE To automatically synchronize the day and time of the log GigaSync must be connected to a network with internet access User The user option allows access to some actions relate...

Page 36: ...ult login credentials Reboot Hardware Full hardware reset Without turning off the doors Reboot Restarts all services software only does not affect hardware Sign out Close the session directly and the...

Page 37: ...race the exact component as needed or in case of failure It also indicates the presence of the power supply and the sync source depending on CMD module base unit o Blue circle indicates power supply v...

Page 38: ...or confirmation with a sign like the following If this is not displayed the change may not have been made General information View general GigaSync information including input line voltage and total o...

Page 39: ...tify the variation and also shows the current value Free RAM memory of the control module in Bytes Data on the software and firmware version of the 2 CPU Type of license and serial number Period of us...

Page 40: ...GigaSync must be connected to a network with Internet access In the current version of the system it is possible to change NTP servers from the SSH interface Cartridges CRT 1 CRT 2 and CRT 3 represent...

Page 41: ...ff Information Description Name Modifiable according to your needs Status Depending on the condition it can be in On Off or Error Keys Type of GigaKey key inserted missing does not have GigaKey wrong...

Page 42: ...th this source it will also be possible to have GPS positioning data coordinates and altitude and the number of satellites connected o SYNC IN RJ12 port to get the sync pulse from another device Sync...

Page 43: ...the following link https filezilla project org To perform the software update procedure you must complete the following steps Download the 9dot update file that can be found at https 9dot it in the do...

Page 44: ...entering the corresponding number and hitting enter A warning sign will appear asking us if we are sure we want to make the change ATTENTION Be careful to upload the correct package for your device I...

Page 45: ...e www skylinkstelecoms ie VanCo U okol doven 9 143 00 Praha 12 Czech Republic 420 246 035 451 obchod vanco cz www vanco cz Wifidom Offices Calle Valencia 63 08015 Barcelona Spain Headquarters Avenida...

Page 46: ...Union and the United Kingdom Copyright 2020 9dot GigaSync is a registered trademark of 9dot S r l in the European Union and the United Kingdom Copyright 2017 9dot All other registered and unregistere...

Reviews: