  4a.  Connect positive (+) red clamp to vehicle battery’s 

positive terminal.

  4b.  Connect negative (–) black clamp to chassis or a 

solid, non-moving, metal vehicle component or body 

part. Never clamp directly to negative battery terminal 

or moving part. Refer to the automobile owner’s 

manual.

5.  Procedure for jump-starting POSITIVE GROUND 

SYSTEMS

   

Note:

 In the rare event that the vehicle to be started has 

a Positive Grounded System (positive battery terminal is 

connected to chassis), replace steps 4a and 4b above 

with steps 5a and 5b, then proceed to step 6.

  5a.  Connect negative (–) black clamp to vehicle battery’s 

negative terminal.

  5b.  Connect positive (+) red clamp to vehicle chassis or a 

solid, non-moving, metal vehicle component or body 

part. Never clamp directly to positive battery terminal 

or moving part. Refer to the automobile owner’s 

manual.

6. When clamps are connected properly, press the unit on/

off button to turn the jump-starter on. A beep will sound, 

the LCD backlight will turn on for 5 seconds and the LCD 

screen will display the following to indicate the unit is in 

standby mode:

   The digital display shows the unit’s internal battery 

voltage. The 5V USB icon will display and the bars on the 

battery icon will light solid to represent the capacity level 

of the unit’s internal battery.

7. Press the jump-starter power button. The LCD screen  

will display the following to indicate the unit is ready to 

jump-start: 

If the surrounding ambient temperature drops to an 

extremely low level during operation, the jump starter icon 

on the LCD screen will flash and all the functions will stop. 

Disconnect the jump starter and allow the unit to warm up 

for several minutes.
If the surrounding ambient temperature rises to an 

extremely high level during operation, the jump starter icon 

on the LCD screen will flash and all the functions will stop. 

Disconnect the jump starter and allow the unit to cool down 

for several minutes. Make sure there is adequate ventilation 

around the unit before attempting to jump start again.
If the clamps are disconnected from the battery, the battery 

clamps icons ( 

 ) on the LCD screen will flash until the 

clamps are connected.
If the clamps are

 incorrectly

 connected with regard to 

polarity, the “–” and “+” signs under the battery clamps icon  

 ) on the LCD screen will flash and an alarm will 

sound continuously until the clamps are disconnected. 

Disconnect the clamps and reconnect with proper 

polarity.

If the unit encounters a short-circuit condition, the arrows 

pointing to the “–” and “+” sign under the battery clamps 

icon ( 

 ) on the LCD screen will flash and the alarm will 

sound continuously until the clamps are disconnected. 

Disconnect the clamps, and discontinue the jump-

starting procedure:

a) Check the wires for damage. If damage is detected, 

return to manufacturer for replacement immediately.

b) Assure that the vehicle has a 12 volt DC battery system. 

This jump-starter is to be used ONLY on vehicles with  

12 volt DC battery systems.

Note: 

The LCD will automatically return to standby mode 

after 30 seconds.

Summary of Contents for RP828-AUOXY

Page 1: ...Black Cyan Magenta Yellow Code RP828 AUOXY IM Date 110427 Edition 03 Op DCR INSTRUCTION MANUAL RP828 AUOXY 300 AMP Portable Lithium Ion Jump Starter ...

Page 2: ...oduction 3 Environmental protection 3 Specifications 3 Instruction manual 3 Safety instructions 3 Specific safety instructions for jump starters 4 Additional safety instructions for batteries and chargers 5 Know your product 6 Charging recharging 7 Operation guide 7 Troubleshooting 10 ...

Page 3: ... Read all of this manual carefully before using the appliance The use of any accessory or attachment or the performance of any operation with this appliance other than those recommended in this instruction manual may present a risk of personal injury Using your appliance This appliance is not intended for use by young or infirm persons without supervision Use in a dry location only Do not allow th...

Page 4: ...lead acid batteries when charging and under extreme conditions battery leakage may occur Ensure the area is well ventilated when conducting jump starting and charging procedures The appliance must only be connected to a 12V lead acid battery Do not use the appliance for charging dry cell batteries that are commonly used with home appliances These batteries may burst and cause injury to persons and...

Page 5: ...Recharge this unit fully after each use Always store the battery clamps in the built in holsters when not in use Additional safety instructions for batteries and chargers Batteries Never attempt to open the unit s body casing for any reason Do not expose the battery to water Do not store in locations where the temperature may exceed 40 C Charge only at ambient temperatures between 4 C and 40 C Cha...

Page 6: ...C charging socket 7 Jump starter power button 8 Cord storage 9 Positive red clamp 10 Negative black clamp 11 AC charging adaptor 12 Clamps icon 13 Battery voltage indicator 14 Battery icon 15 USB icon 16 Jump starter icon 17 Short circuit icon 18 Polarity icon 19 Digital display 1 5 8 10 15 12 2 3 4 7 9 13 14 16 17 18 6 6 11 19 ...

Page 7: ...n represent the capacity level of the unit s internal battery The bars on the battery icon will change from empty to solid bottom to top repeatedly to indicate the unit is charging Note If the unit on off button is pressed while the AC charging adapter is plugged in the LCD screen will display the following The digital display shows the unit s internal battery voltage The 5V USB icon will display ...

Page 8: ...art If the surrounding ambient temperature drops to an extremely low level during operation the jump starter icon on the LCD screen will flash and all the functions will stop Disconnect the jump starter and allow the unit to warm up for several minutes If the surrounding ambient temperature rises to an extremely high level during operation the jump starter icon on the LCD screen will flash and all...

Page 9: ...ll display as shown in the second part of step 7 of the directions Disconnect clamps and reconnect to battery with correct polarity If the vehicle fails to start turn off the ignition press the jump starter power button then the unit on off button to turn the unit off disconnect the jump start system s leads and contact a qualified technician to investigate why the engine did not start Recharge th...

Page 10: ...mp starter instructions carefully Refer to the important notes included in this section that explain common problems and solutions Make sure a proper polarity cable connection has been established Check that unit has a full charge Recharge unit if necessary LED area light does not come on Make sure the unit on off button and the LED area light on off button have been pressed to turn the unit and L...

Page 11: ...11 ...

Page 12: ......

Reviews: