909 RP828-AUOXY Instruction Manual Download Page 7

7

Charging / recharging

Lithium-Ion batteries require routine maintenance to 

ensure a full charge and long battery life. All batteries lose 

energy from self-discharge over time and more rapidly 

when they are at higher temperatures. Therefore, batteries 

need periodic charging to replace energy lost through 

self-discharge. When the unit is not in frequent use, 

manufacturer recommends the battery be recharged  

at least every 6 months.

IMPORTANT:

 If you attempt to use the unit when the unit’s 

battery charge level is too low, the unit will automatically 

shut down. Immediately recharge the unit with all other 

functions turned off.

Notes: 

This unit is delivered in a partially charged state 

– you must fully charge it after purchase and before using 

it for the first time. Initial AC charge should be for up to 20 

hours or until the unit shows as fully charged.
Recharging battery after each use will prolong battery 

life; frequent heavy discharges between recharges and/or 

overcharging will reduce battery life.
Make sure all other unit functions are turned OFF during 

recharging, as this can slow the recharging process.

AC charging 

1. Insert the jack plug of AC (mains) charging adapter into 

the 12V AC/DC charging socket on the side of the unit. 

Insert the mains charging adapter into a mains power 

socket. A beep will sound, the LCD backlight will turn on 

5 seconds and the LCD screen will display the following: 

   The bars on the battery icon represent the capacity level 

of the unit’s internal battery. The bars on the battery icon 

will change from empty to solid (bottom to top) repeatedly 

to indicate the unit is charging. 

Note:

 If the unit on/off button is pressed while the AC 

charging adapter is plugged in, the LCD screen will display 

the following: 

The digital display shows the unit’s internal battery voltage. 

The 5V USB icon will display and the bars on the battery 

icon will continue to change from empty to solid (bottom to 

top) repeatedly to indicate the unit is still charging. 
2. Charge for up to 20 hours or until the unit is fully charged. 

The unit is fully charged when the battery icon shows 4 

solid bars. 

3. When charging is complete, unplug the AC charging 

adapter from the mains power socket, then disconnect 

the jack plug of the AC charging adapter from the 12V 

AC/DC charging port. Store the charger in a dry, safe 

place. 

Operation guide 

Jump-starter

This unit is equipped with a jump-starter power button 

that allows energy to flow only when proper connections 

are made to battery and frame. Take the following steps, 

observing all cautions and warnings in the “Safety 

Instructions” section at the front of this manual
1. Turn off vehicle ignition and all accessories (radio, A/C, 

lights, connected cell phone chargers, etc.). Place vehicle 

in “park” and set the emergency brake. 

2. Make sure the unit on/off button and jump-starter power 

button are turned off.

3. Remove jumper clamps from clamp holders. Connect the 

red clamp first, then the black clamp. 

4. Procedure for jump-starting a NEGATIVE GROUNDED 

SYSTEM (negative battery terminal is connected to 

chassis) (MOST COMMON)

Summary of Contents for RP828-AUOXY

Page 1: ...Black Cyan Magenta Yellow Code RP828 AUOXY IM Date 110427 Edition 03 Op DCR INSTRUCTION MANUAL RP828 AUOXY 300 AMP Portable Lithium Ion Jump Starter ...

Page 2: ...oduction 3 Environmental protection 3 Specifications 3 Instruction manual 3 Safety instructions 3 Specific safety instructions for jump starters 4 Additional safety instructions for batteries and chargers 5 Know your product 6 Charging recharging 7 Operation guide 7 Troubleshooting 10 ...

Page 3: ... Read all of this manual carefully before using the appliance The use of any accessory or attachment or the performance of any operation with this appliance other than those recommended in this instruction manual may present a risk of personal injury Using your appliance This appliance is not intended for use by young or infirm persons without supervision Use in a dry location only Do not allow th...

Page 4: ...lead acid batteries when charging and under extreme conditions battery leakage may occur Ensure the area is well ventilated when conducting jump starting and charging procedures The appliance must only be connected to a 12V lead acid battery Do not use the appliance for charging dry cell batteries that are commonly used with home appliances These batteries may burst and cause injury to persons and...

Page 5: ...Recharge this unit fully after each use Always store the battery clamps in the built in holsters when not in use Additional safety instructions for batteries and chargers Batteries Never attempt to open the unit s body casing for any reason Do not expose the battery to water Do not store in locations where the temperature may exceed 40 C Charge only at ambient temperatures between 4 C and 40 C Cha...

Page 6: ...C charging socket 7 Jump starter power button 8 Cord storage 9 Positive red clamp 10 Negative black clamp 11 AC charging adaptor 12 Clamps icon 13 Battery voltage indicator 14 Battery icon 15 USB icon 16 Jump starter icon 17 Short circuit icon 18 Polarity icon 19 Digital display 1 5 8 10 15 12 2 3 4 7 9 13 14 16 17 18 6 6 11 19 ...

Page 7: ...n represent the capacity level of the unit s internal battery The bars on the battery icon will change from empty to solid bottom to top repeatedly to indicate the unit is charging Note If the unit on off button is pressed while the AC charging adapter is plugged in the LCD screen will display the following The digital display shows the unit s internal battery voltage The 5V USB icon will display ...

Page 8: ...art If the surrounding ambient temperature drops to an extremely low level during operation the jump starter icon on the LCD screen will flash and all the functions will stop Disconnect the jump starter and allow the unit to warm up for several minutes If the surrounding ambient temperature rises to an extremely high level during operation the jump starter icon on the LCD screen will flash and all...

Page 9: ...ll display as shown in the second part of step 7 of the directions Disconnect clamps and reconnect to battery with correct polarity If the vehicle fails to start turn off the ignition press the jump starter power button then the unit on off button to turn the unit off disconnect the jump start system s leads and contact a qualified technician to investigate why the engine did not start Recharge th...

Page 10: ...mp starter instructions carefully Refer to the important notes included in this section that explain common problems and solutions Make sure a proper polarity cable connection has been established Check that unit has a full charge Recharge unit if necessary LED area light does not come on Make sure the unit on off button and the LED area light on off button have been pressed to turn the unit and L...