909 RP828-AUOXY Instruction Manual Download Page 5

5

  Excessive engine cranking can damage the vehicle‘s 

starter motor.  

If the engine fails to start after the recommended number 

of attempts, discontinue jump-starting procedures and 

look for other problems that need to be corrected. 

  This appliance is not designed to be used as a 

replacement for a vehicular battery. Do not attempt to 

operate a vehicle that does not have a battery installed. 

  This appliance contains a Lithium-Ion battery. It is 

recommended that the appliance is laid flat during 

storage, use, and recharging. 

  To reduce the risk of electric shock, disconnect the 

appliance from any power source before attempting 

maintenance or cleaning. Turning off controls without 

disconnecting the appliance will not reduce this risk. 

  Make sure the appliance is disconnected from all 

charging power sources before beginning the jump-start 

procedure. 

  If the connections to the battery’s positive and negative 

terminals are incorrect, the reverse polarity indicator will 

light and the unit will sound a warning until the clamps 

are disconnected. Rectify the connections immediately.

  If vehicle fails to start, turn off the ignition, turn off the 

Jump-Starter Power Switch, disconnect the jump-start 

system’s leads and contact a qualified technician to 

investigate why the engine did not start.

  Recharge this unit fully after each use.

  Always store the battery clamps in the built-in holsters 

when not in use. 

Additional safety instructions  

for batteries and chargers 

Batteries 

  Never attempt to open the unit’s body casing for any 

reason. 

  Do not expose the battery to water. 

  Do not store in locations where the temperature may 

exceed 40°C. 

  Charge only at ambient temperatures between 4°C  

and 40°C. 

  Charge only using the chargers provided with the 

appliance. 

  When disposing of batteries, follow the instructions given 

in the section “Protecting the environment”.

  Under extreme conditions, battery leakage may occur.  

When you notice liquid on the batteries, carefully wipe  

the liquid off using a cloth. Avoid skin contact.

Chargers 

Your charger has been designed for a specific voltage. 

Always check that the mains voltage corresponds to the 

voltage on the rating plate.

WARNING! 

Never attempt to replace the charger unit with 

a regular mains plug. Use your charger only to charge the 

battery in the tool with which it was supplied. Other batteries 

could  burst, causing personal injury and damage.

WARNING! 

Use your charger only to charge the battery in 

the tool with which it was supplied. Other batteries could 

burst, causing personal injury and damage.

  Never attempt to charge non-rechargeable batteries.

  Have defective cords replaced immediately. 

  Do not expose the charger to water. 

  Do not open the charger.

  Do not probe the charger. 

  The battery must be placed in a well ventilated area  

when charging. 

Summary of Contents for RP828-AUOXY

Page 1: ...Black Cyan Magenta Yellow Code RP828 AUOXY IM Date 110427 Edition 03 Op DCR INSTRUCTION MANUAL RP828 AUOXY 300 AMP Portable Lithium Ion Jump Starter ...

Page 2: ...oduction 3 Environmental protection 3 Specifications 3 Instruction manual 3 Safety instructions 3 Specific safety instructions for jump starters 4 Additional safety instructions for batteries and chargers 5 Know your product 6 Charging recharging 7 Operation guide 7 Troubleshooting 10 ...

Page 3: ... Read all of this manual carefully before using the appliance The use of any accessory or attachment or the performance of any operation with this appliance other than those recommended in this instruction manual may present a risk of personal injury Using your appliance This appliance is not intended for use by young or infirm persons without supervision Use in a dry location only Do not allow th...

Page 4: ...lead acid batteries when charging and under extreme conditions battery leakage may occur Ensure the area is well ventilated when conducting jump starting and charging procedures The appliance must only be connected to a 12V lead acid battery Do not use the appliance for charging dry cell batteries that are commonly used with home appliances These batteries may burst and cause injury to persons and...

Page 5: ...Recharge this unit fully after each use Always store the battery clamps in the built in holsters when not in use Additional safety instructions for batteries and chargers Batteries Never attempt to open the unit s body casing for any reason Do not expose the battery to water Do not store in locations where the temperature may exceed 40 C Charge only at ambient temperatures between 4 C and 40 C Cha...

Page 6: ...C charging socket 7 Jump starter power button 8 Cord storage 9 Positive red clamp 10 Negative black clamp 11 AC charging adaptor 12 Clamps icon 13 Battery voltage indicator 14 Battery icon 15 USB icon 16 Jump starter icon 17 Short circuit icon 18 Polarity icon 19 Digital display 1 5 8 10 15 12 2 3 4 7 9 13 14 16 17 18 6 6 11 19 ...

Page 7: ...n represent the capacity level of the unit s internal battery The bars on the battery icon will change from empty to solid bottom to top repeatedly to indicate the unit is charging Note If the unit on off button is pressed while the AC charging adapter is plugged in the LCD screen will display the following The digital display shows the unit s internal battery voltage The 5V USB icon will display ...

Page 8: ...art If the surrounding ambient temperature drops to an extremely low level during operation the jump starter icon on the LCD screen will flash and all the functions will stop Disconnect the jump starter and allow the unit to warm up for several minutes If the surrounding ambient temperature rises to an extremely high level during operation the jump starter icon on the LCD screen will flash and all...

Page 9: ...ll display as shown in the second part of step 7 of the directions Disconnect clamps and reconnect to battery with correct polarity If the vehicle fails to start turn off the ignition press the jump starter power button then the unit on off button to turn the unit off disconnect the jump start system s leads and contact a qualified technician to investigate why the engine did not start Recharge th...

Page 10: ...mp starter instructions carefully Refer to the important notes included in this section that explain common problems and solutions Make sure a proper polarity cable connection has been established Check that unit has a full charge Recharge unit if necessary LED area light does not come on Make sure the unit on off button and the LED area light on off button have been pressed to turn the unit and L...

Page 11: ...11 ...

Page 12: ......