background image

3

Scope of product

This product is suited for lighting and camping.
It is not recommended to be used with any  

electronic devices. 

Description of symbols

The rating plate on your tool may show symbols.  

These represent important information about the  

product or instructions on its use.

Wear hearing protection.  

Wear eye protection.  

Wear breathing protection.

Conforms to relevant standards  

for electromagnetic compatibility.

Specifications

AC Output: 

240Vac ~ 50Hz

Rated Power: 

650W

Peak Power: 

720W

Phase: 

Single

Power Factor: 

coso- =1

Displacement: 

63cc

Engine: 

2HP, 2 stroke

No Load Speed: 

3000 RPM

Fuel Tank Capacity: 

4.2L

Fuel Type:  

2 Stroke (petrol / oil mixture)

Oil Type:  

2 Stroke

Fuel Mixture:  

Unleaded petrol / 

   

2-stroke oil (50:1) 

Note.

   

Ethanol Unleaded fuel  

 

is NOT recommended

Spark Plug:   

F5TC 

Equivalent Spark Plugs:  Bosch W5CC 

   

NGK BP5ES 

   

CHAMPION N12YC

Operation Noise Level:  

68dB/7m

Net Weight:  

17kg

Introduction

Your new 909 power tool will more than satisfy 

your expectations. It has been manufactured under 

stringent 909 Quality Standards to meet superior 

performance criteria.
You will find your new tool easy and safe to operate, 

and, with proper care, it will give you many years 

of dependable service.

CAUTION.

 

Carefully read through this entire Instruction 

Manual before using your new 909 Power Tool. Take 

special care to heed the Cautions and Warnings.
Your 909 power tool has many features that will make 

your job faster and easier. Safety, performance, and 

dependability have been given top priority in the 

development of this tool, making it easy to maintain 

and operate.

Environmental protection

Recycle unwanted materials instead 

of disposing of them as waste. All tools, 

hoses and packaging should be sorted, 

taken to the local recycling centre and 

disposed of in an environmentally safe way.

Summary of Contents for A750

Page 1: ...Black Cyan Magenta Yellow Code A750 Date 101125 Edition 03 Op AB INSTRUCTION MANUAL A750 720W GENERATOR ...

Page 2: ... parts 8 Risk from lifting 8 Additional safety rules for generators 9 Unpacking 9 Know your product 10 What can I use this generator for 11 Fitting the handle 11 Mixing the fuel 11 Filling the fuel tank 11 Starting the engine 12 Stopping the engine 12 Connecting apparatus to the generator AC 12 AC overload cut out 13 Periodic maintenance 13 Generator maintenance 13 Storage 13 Spark plugs 14 Air fi...

Page 3: ...park Plugs Bosch W5CC NGK BP5ES CHAMPION N12YC Operation Noise Level 68dB 7m Net Weight 17kg Introduction Your new 909 power tool will more than satisfy your expectations It has been manufactured under stringent 909 Quality Standards to meet superior performance criteria You will find your new tool easy and safe to operate and with proper care it will give you many years of dependable service CAUT...

Page 4: ... it was not intended 7 Dress correctly Do not wear loose clothing or jewellery They can be caught in moving parts Rubber gloves and non slip footwear are recommended when working outdoors If you have long hair wear a protective hair covering 8 Use safety accessories Safety glasses and earmuffs should always be worn A face or dust mask is also required if the drilling operation creates dust 9 Secur...

Page 5: ...ctrical current could charge conductive surfaces in contact with the generator Place generator on low conductivity surface such as a concrete slab ALWAYS operate generator a minimum of 2 meters from any conductive surface Use of worn damaged or ungrounded extension cords Contact with worn or damaged extension cords could result in electrocution Use of ungrounded cordsets could prevent operation of...

Page 6: ...ovide safe operation Tampering with the engine speed adjustment could result in overheating of attachments and could cause a fire Never attempt to speed up the engine to obtain more performance Both the output voltage and frequency will be thrown out of standard by this practice endangering attachments and the user Inadequate ventilation for generator Materials placed against or near the generator...

Page 7: ...o prevent it Gasoline engines produce toxic carbon monoxide exhaust fumes Breathing exhaust fumes will cause serious injury or death Operate generator in clean dry well ventilated area Never operate unit in enclosed areas such as garages basements storage sheds or in any location occupied by humans or animals Keep children pets and others away from area of operating unit Risk of unsafe operation H...

Page 8: ... Hazard What could happen How to prevent it Contact with moving parts can result in serious injury The generator contains parts which rotate at high speed during operation These parts are covered by guarding to prevent injury Never operate generator with guarding or cover plates removed Avoid wearing loose fitting clothing or jewellery which could be caught by moving parts Risk from lifting Hazard...

Page 9: ...ep your distance The generator emits exhaust fumes As a safety precaution do not stand close to the unit whilst it is in operation Ensure bystanders also keep their distance 9 Ensure you use oil mix fuel Ensure that you mix 50 parts unleaded fuel to 1 part 2 stroke grade oil If not mixed correctly at 50 1 the engine will overheat and cause damage to your generator 10 Never fill fuel tank indoors N...

Page 10: ...your product 1 Handle 2 Fuel cap 3 Fuel tank 4 Fuel tap 5 Recoil starter 6 On off switch 7 Choke 8 Air filter cover 9 Tap extension fuel filter 10 AC Output 240V 11 AC circuit breaker 4 5 3 2 1 6 7 8 10 4 9 11 ...

Page 11: ... fitted under the heads of the screws Mixing the fuel 1 The generator uses unleaded fuel and 2 stroke grade oil Note Ethanol unleaded fuel is NOT recommended 2 You need to mix both unleaded fuel and 2 stroke oil together 3 The proportion should be 50 parts unleaded fuel and 1 part 2 stroke oil Quick reference common fuel mixture requirements for 50 1 is 1 Litre of unleaded fuel mixed with 20mL of ...

Page 12: ...engine has been operating for 10 15 seconds slowly return the choke lever back to the right hand side position This position will switch the choke off Note If the generator stops move the choke back to the full left hand side and repeat the starting operation Stopping the engine 1 Before stopping ensure that no electrical apparatus is connected to the generator 2 Press O on the engine switch 6 to ...

Page 13: ...t the overload cut out switch cool down 4 If it is an AC apparatus causing the overload push the AC circuit breaker button 11 5 When re connecting appliances reduce the load to that which previously overloaded the generator Periodic maintenance Items Remarks Every 50hrs or every month Every 150 hrs or every month Spark Plug Remove Carbon x Air Filter Cleaning x Fuel Filters Clean x Decarbon isatio...

Page 14: ... air filter element in place Tap extension fuel filter A small fuel filter has been fitted to the inlet side of the fuel tap 4 inside the tank This tap extension fuel filter 9 prevents any dirt in the fuel from entering the fuel system The procedure for removing this filter in order to replace or clean it is given below Note the following procedure should be performed in a well ventilated area wit...

Page 15: ...the tank with fuel and ensure there are no leaks between the tap and the tank and with the fuel tap turned on ensure there are no leaks where the fuel hose is fitted to the outlet of the tap Petrol tank filter 1 Stop the engine 2 Turn the fuel tap 4 to the off position 3 The petrol tank filter is located directly under the petrol cap This protects impurities entering the fuel tank during refuellin...

Page 16: ...ark plug wire loose 7 Attach wire to spark plug 8 Dirty fuel filters 8 Clean filters as per instructions No electrical output 1 Faulty receptacle 1 Have service centre replace receptacle 2 Circuit breaker kicked out 2 Depress and reset 3 Defective capacitor 3 Have service centre replace capacitor 4 Faulty power cord 4 Replace cord Repeated circuit breaker tripping 1 Overload 1 Reduce load 2 Faulty...

Page 17: ......