If the attached motorized camera is not on the support driver list, choose the proper UART
interface and pull down the driver list to select Custom Camera type and click on
for further configuration.
Setup the serial "
Port Settings
" according to the instruction manual of the custom camera. The
"
Baud Rate (bps)
" of the serial port is up to 115200 bps. Then enter the specific command
related to PTZ in the respective field. The custom command for "
Control Setting
" should be
edited in ASCII format. Video Server will interpret the ASCII format command to binary string.
For instance, “012000ABCD” will be sent out of the COM port as five hexadecimal bytes of 01,
20, 00, AB and CD. If the command string is composed of two or more commands, a comma ‘,’
should be inserted to separate each command. Each comma represents 200 milliseconds. For
instance, a command to pan left may be “01000305” and a command to stop panning may be